Measuring blood pressure in small laboratory animals
Abstract
The most common techniques currently employed for monitoring blood pressure (BP) in conscious rats and mice are the tail cuff and the exteriorized catheter that feeds a pressure transducer located outside the cage. There are, however, considerable drawbacks associated with these methods, which in many respects make each of these techniques undesirable as an accurate means of obtaining pressure measurements. Recent studies have shown that measurements of physiological variables, such as electrocardiogram (ECG), heart rate (HR), and body temperature (BT), from freely moving rats and mice by using implantable radiotelemetry were more efficient, reliable and less labour intensive when compared to measurement techniques described in the literature so far. Nowadays, measurement of BP by radiotelemetry has been described and validated for many laboratory animal species, including rats and mice. The implantable radiotelemetry technique can circumvent many of the problems associated with conventional methods (tail cuff; exteriorized catheters) of BP monitoring in mice and rats. This chapter describes the surgical aspects of the radiotelemetry techniques currently used to monitor and measure blood pressure in awake animals.
Similar articles
-
Surgical procedure for implanting a radiotelemetry transmitter to monitor ECG, heart rate and body temperature in small Carassius auratus and Carassius auratus gibelio under laboratory conditions.Lab Anim. 2006 Oct;40(4):465-8. doi: 10.1258/002367706778476325. Lab Anim. 2006. PMID: 17018217
-
Comparison of simultaneous measurement of mouse systolic arterial blood pressure by radiotelemetry and tail-cuff methods.Am J Physiol Heart Circ Physiol. 2004 Jun;286(6):H2408-15. doi: 10.1152/ajpheart.01089.2003. Epub 2004 Feb 12. Am J Physiol Heart Circ Physiol. 2004. PMID: 14962829
-
Blood pressure and heart rate determination by radiotelemetry in mice.J Gravit Physiol. 2001 Jul;8(1):P61-2. J Gravit Physiol. 2001. PMID: 12638626
-
The use of radiotelemetry in small laboratory animals: recent advances.Contemp Top Lab Anim Sci. 2001 Jan;40(1):8-16. Contemp Top Lab Anim Sci. 2001. PMID: 11300669 Review.
-
Evaluation and applications of radiotelemetry in small laboratory animals.Physiol Genomics. 2003 May 13;13(3):197-205. doi: 10.1152/physiolgenomics.00164.2002. Epub 2003 May 13. Physiol Genomics. 2003. PMID: 12746464 Review.
Cited by
-
Measurement of invasive blood pressure in rats.J Pharmacol Pharmacother. 2012 Apr;3(2):172-7. doi: 10.4103/0976-500X.95521. J Pharmacol Pharmacother. 2012. PMID: 22629093 Free PMC article.
-
Non-restraining EEG Radiotelemetry: Epidural and Deep Intracerebral Stereotaxic EEG Electrode Placement.J Vis Exp. 2016 Jun 25;(112):54216. doi: 10.3791/54216. J Vis Exp. 2016. PMID: 27404845 Free PMC article.
-
Guidelines for assessment of cardiac electrophysiology and arrhythmias in small animals.Am J Physiol Heart Circ Physiol. 2022 Dec 1;323(6):H1137-H1166. doi: 10.1152/ajpheart.00439.2022. Epub 2022 Oct 21. Am J Physiol Heart Circ Physiol. 2022. PMID: 36269644 Free PMC article. Review.
-
EEG Radiotelemetry in Small Laboratory Rodents: A Powerful State-of-the Art Approach in Neuropsychiatric, Neurodegenerative, and Epilepsy Research.Neural Plast. 2016;2016:8213878. doi: 10.1155/2016/8213878. Epub 2015 Dec 24. Neural Plast. 2016. PMID: 26819775 Free PMC article. Review.
-
The cardiovascular and endocrine responses to voluntary and forced diving in trained and untrained rats.Am J Physiol Regul Integr Comp Physiol. 2010 Jan;298(1):R224-34. doi: 10.1152/ajpregu.00592.2009. Epub 2009 Nov 18. Am J Physiol Regul Integr Comp Physiol. 2010. PMID: 19923359 Free PMC article.