Abstract
Purpose: To see if locking volar plates approach the strength of dorsal plates on a dorsally comminuted distal radius fracture model. Volar plates have been associated with fewer tendon complications than dorsal plates but are thought to have mechanical disadvantages in dorsally comminuted distal radius fractures. Locking plates may increase construct strength and stiffness. This study compares dorsal and volar locking and nonlocking plates in a dorsally comminuted distal radius fracture model.
Methods: Axial loading was used to test 14 pairs of embalmed radii after an osteotomy simulating dorsal comminution and plating in 1 of 4 configurations: a standard nonlocking 3.5-mm compression T-plate or a 3.5-mm locking compression T-plate applied either dorsally or volarly. Failure was defined as the point of initial load reduction caused by bone breakage or substantial plate bending.
Results: No significant differences in stiffness or failure strength were found between volar locked and nonlocked constructs. Although not significant, the stiffness of dorsal locked constructs was 51% greater than that of the nonlocked constructs. Locked or nonlocked dorsal constructs were more than 2 times stiffer than volar constructs. The failure strength of dorsal constructs was 53% higher than that of volar constructs. Failure for both volar locked and nonlocked constructs occurred by plate bending through the unfilled hole at the osteotomy site. Failure for both dorsal locked and nonlocked constructs occurred by bone breakage.
Conclusions: Locking plates failed to increase the stiffness or strength of dorsally comminuted distal radius fractures compared with nonlocking plates. Failure strength and stiffness are greater for locked or nonlocked dorsal constructs than for either locked or nonlocked volar constructs. Whether the lower stiffness and failure strength are of clinical significance is unknown. The unfilled hole at the site of comminution or osteotomy is potentially a site of weakness in both volar locked and nonlocked plates.
Similar articles
-
Mechanical characteristics of locking and compression plate constructs applied dorsally to distal radius fractures.J Hand Surg Am. 2007 May-Jun;32(5):623-9. doi: 10.1016/j.jhsa.2007.03.005. J Hand Surg Am. 2007. PMID: 17481999
-
Does a volar locking plate provide equivalent stability as a dorsal nonlocking plate in a dorsally comminuted distal radius fracture?: a biomechanical study.J Orthop Trauma. 2008 Oct;22(9):605-10. doi: 10.1097/BOT.0b013e318186006f. J Orthop Trauma. 2008. PMID: 18827589
-
Volar versus dorsal locking plates with and without radial styloid locking plates for the fixation of dorsally comminuted distal radius fractures: A biomechanical study in cadavers.J Hand Surg Am. 2006 Dec;31(10):1587-93. doi: 10.1016/j.jhsa.2006.09.011. J Hand Surg Am. 2006. PMID: 17145377
-
[Biomechanical study of four palmar locking plates and one non-locking palmar plate for distal radius fractures: stiffness and load to failure tests in a cadaver model].Biomed Tech (Berl). 2009 Jun;54(3):150-8. doi: 10.1515/BMT.2009.018. Biomed Tech (Berl). 2009. PMID: 19469665 Review. German.
-
Volar plate fixation of distal radius fractures.Hand Clin. 2005 Aug;21(3):347-54. doi: 10.1016/j.hcl.2005.02.003. Hand Clin. 2005. PMID: 16039446 Review.
Cited by
-
Dacron--silicone prosthesis for the metacarpophalangeal and interphalangeal joints.Hand. 1971 Mar;3(1):55-61. doi: 10.1016/0072-968x(71)90012-x. Hand. 1971. PMID: 4999719 No abstract available.
-
Biomechanics of Subcutaneous Locked Plating Versus Burke Plate and External Fixator for Comminuted Distal Radius Fractures.Cureus. 2023 May 17;15(5):e39142. doi: 10.7759/cureus.39142. eCollection 2023 May. Cureus. 2023. PMID: 37332475 Free PMC article.
-
Volar Locking Plate Fixations for Displaced Distal Radius Fractures: An Evaluation of Complications and Radiographic Outcomes.Hand (N Y). 2018 Jul;13(4):466-472. doi: 10.1177/1558944717717505. Epub 2017 Jul 9. Hand (N Y). 2018. PMID: 28691543 Free PMC article.
-
Union of an intra-articular distal radius fracture after successive failures of three locking plates: a case report.Strategies Trauma Limb Reconstr. 2012 Apr;7(1):45-50. doi: 10.1007/s11751-012-0127-6. Epub 2012 Jan 26. Strategies Trauma Limb Reconstr. 2012. PMID: 22278597 Free PMC article.
-
[Volar locking compression plating versus dorsal plating for fractures of the distal radius: a prospective, randomized study].Unfallchirurg. 2009 Aug;112(8):712-8. doi: 10.1007/s00113-008-1526-5. Unfallchirurg. 2009. PMID: 19597773 Clinical Trial. German.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical