Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2005 Jun;31(6):1104-13.
doi: 10.1016/j.jcrs.2004.10.051.

Excimer laser photorefractive keratectomy for hyperopia: 7.5-year follow-up

Affiliations
Clinical Trial

Excimer laser photorefractive keratectomy for hyperopia: 7.5-year follow-up

David P S O'Brart et al. J Cataract Refract Surg. 2005 Jun.

Abstract

Purpose: To report the results of a long-term prospective study to evaluate refractive stability and safety of hyperopic photorefractive keratectomy (H-PRK).

Setting: Department of Ophthalmology, St. Thomas' Hospital, London, United Kingdom.

Methods: Twenty-one patients (49%) (40 eyes) of cohort of 43 patients who participated in 1 of the first clinical trials of H-PRK were assessed at a mean follow-up of 90.7 months (range 62 to 106 months). The H-PRK was performed using a Summit Technology Apex Plus Excimer laser (Summit Technology, Inc.). The mean preoperative spherical equivalent refraction (SEQ) was +4.70 diopters (D) (range +2.00 to +7.50 D). Patients were allocated to 1 of 4 treatment groups based on their preoperative refraction and received 1 of the following spherical corrections: +1.50 D, +3.00 D, +4.50 D, or +6.00 D.

Results: At 7.5 years, the refractive correction remained stable with a mean difference in SEQ between 1 year and 7.5 years of +0.28 D. The mean manifest SEQ was +0.83 D (range +5.00 to -3.00 D). Sixty-seven percent of eyes having corrections of +1.50 D and +3.00 D were within +/-1.00 D of the predicted correction. Predictability was poorer with +4.50 D and +6.00 D corrections, with 40% of eyes within +/-1.00 D of that expected. An improvement in uncorrected near acuity was achieved in 35 eyes (87.5%), and 35 eyes (87.5%) showed an improvement in uncorrected distance acuity from preoperative levels. Best spectacle-corrected visual acuity (BSCVA) was unchanged or improved from preoperative values in 25 eyes (62.5%). Three eyes (8%) lost 2 lines of Snellen BSCVA, which in 2 cases was attributable to cataract formation. A peripheral ring of haze, 6.5 mm in diameter, appeared in most eyes. Its intensity was greatest at 6 months and then diminished with time. In 10 eyes (25%), remnants of the haze ring were evident at 7.5 years and subepithelial iron rings, 6.5 mm in diameter were evident in 26 eyes (70%). No patient complained of night-vision problems and no eye developed ectasia.

Conclusions: In H-PRK, refractive stability achieved at 1 year was maintained up to 7.5 years with no evidence of hyperopic shift, diurnal fluctuation, or late regression. Peripheral corneal haze decreased with time but was still evident in a number of eyes at the last follow-up visit.

PubMed Disclaimer

Similar articles

Cited by

Publication types