Microvascular blood viscosity in vivo and the endothelial surface layer
- PMID: 16040719
- DOI: 10.1152/ajpheart.00297.2005
Microvascular blood viscosity in vivo and the endothelial surface layer
Abstract
The apparent viscosity of blood in glass tubes declines with decreasing diameter (Fåhraeus-Lindqvist effect) and exhibits a distinctive minimum at 6-7 microm. However, flow resistance in vivo in small vessels is substantially higher than predicted by in vitro viscosity data. The presence of a thick endothelial surface layer (ESL) has been proposed as the primary cause for this discrepancy. Here, a physical model is proposed for microvascular flow resistance as a function of vessel diameter and hematocrit in vivo; it combines in vitro blood viscosity with effects of a diameter-dependent ESL. The model was developed on the basis of flow distributions observed in three microvascular networks in the rat mesentery with 392, 546, and 383 vessel segments, for which vessel diameters, network architecture, flow velocity, and hematocrit were determined by intravital microscopy. A previously described hemodynamic simulation was used to predict the distributions of flow and hematocrit from the assumed model for effective blood viscosity. The dependence of ESL thickness on vessel diameter was estimated by minimizing deviations of predicted values for velocities, flow directions, and hematocrits from measured data. Optimal results were obtained with a layer thickness of approximately 0.8-1 microm for 10- to 40-microm-diameter vessels and declined strongly for smaller diameters, with an additional hematocrit-dependent impact on flow resistance exhibiting a maximum for approximately 10-microm-diameter vessels. These results show that flow resistance in vivo can be explained by in vitro blood viscosity and the presence of an ESL and indicate the rheologically effective thickness of the ESL in microvessels.
Similar articles
-
Blood flow in microvascular networks. Experiments and simulation.Circ Res. 1990 Oct;67(4):826-34. doi: 10.1161/01.res.67.4.826. Circ Res. 1990. PMID: 2208609
-
Resistance to blood flow in microvessels in vivo.Circ Res. 1994 Nov;75(5):904-15. doi: 10.1161/01.res.75.5.904. Circ Res. 1994. PMID: 7923637
-
Microvascular blood flow resistance: Role of red blood cell migration and dispersion.Microvasc Res. 2015 May;99:57-66. doi: 10.1016/j.mvr.2015.02.006. Epub 2015 Feb 25. Microvasc Res. 2015. PMID: 25724979
-
Rheology of the microcirculation.Clin Hemorheol Microcirc. 2003;29(3-4):143-8. Clin Hemorheol Microcirc. 2003. PMID: 14724335 Review.
-
Determinants of tumor blood flow: a review.Cancer Res. 1988 May 15;48(10):2641-58. Cancer Res. 1988. PMID: 3282647 Review.
Cited by
-
Going beyond 20 μm-sized channels for studying red blood cell phase separation in microfluidic bifurcations.Biomicrofluidics. 2016 May 12;10(3):034103. doi: 10.1063/1.4948955. eCollection 2016 May. Biomicrofluidics. 2016. PMID: 27190568 Free PMC article.
-
A computational model of oxygen transport in the cerebrocapillary levels for normal and pathologic brain function.J Cereb Blood Flow Metab. 2013 Oct;33(10):1633-41. doi: 10.1038/jcbfm.2013.119. Epub 2013 Aug 7. J Cereb Blood Flow Metab. 2013. PMID: 23921901 Free PMC article.
-
Morphometric, Hemodynamic, and Biomechanical Factors Influencing Blood Flow and Oxygen Concentration in the Human Lamina Cribrosa.Invest Ophthalmol Vis Sci. 2020 Apr 9;61(4):3. doi: 10.1167/iovs.61.4.3. Invest Ophthalmol Vis Sci. 2020. PMID: 32271886 Free PMC article.
-
Another role for nitric oxide in blood flow control?Med Biol Eng Comput. 2011 Jun;49(6):627-9; discussion 631-2. doi: 10.1007/s11517-011-0762-y. Epub 2011 Mar 30. Med Biol Eng Comput. 2011. PMID: 21448691
-
Insights into cerebral haemodynamics and oxygenation utilising in vivo mural cell imaging and mathematical modelling.Sci Rep. 2018 Jan 22;8(1):1373. doi: 10.1038/s41598-017-19086-z. Sci Rep. 2018. PMID: 29358701 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources