Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Controlled Clinical Trial
. 2005 Dec;99(6):2278-84.
doi: 10.1152/japplphysiol.00713.2005. Epub 2005 Jul 28.

Mean aortic pressure is the geometric mean of systolic and diastolic aortic pressure in resting humans

Affiliations
Free article
Controlled Clinical Trial

Mean aortic pressure is the geometric mean of systolic and diastolic aortic pressure in resting humans

Denis Chemla et al. J Appl Physiol (1985). 2005 Dec.
Free article

Abstract

The aim of our study was twofold: 1) to establish a mathematical link between mean aortic pressure (MAP) and systolic (SAP) and diastolic aortic pressures (DAP) by testing the hypothesis that either the geometric mean or the harmonic mean of SAP and DAP were reliable MAP estimates; and 2) to critically evaluate three empirical formulas recently proposed to estimate MAP. High-fidelity pressures were recorded at rest at the aortic root level in controls (n = 31) and in subjects with various forms of cardiovascular diseases (n = 108). The time-averaged MAP and the pulse pressure (PP = SAP - DAP) were calculated. The MAP ranged from 66 to 160 mmHg [mean = 107.9 mmHg (SD 18.2)]. The geometric mean, i.e., the square root of the product of SAP and DAP, furnished a reliable estimate of MAP [mean bias = 0.3 mmHg (SD 2.7)]. The harmonic mean was inaccurate. The following MAP formulas were also tested: DAP + 0.412 PP (Meaney E, Alva F, Meaney A, Alva J, and Webel R. Heart 84: 64, 2000), DAP + 0.33 PP + 5 mmHg [Chemla D, Hébert JL, Aptecar E, Mazoit JX, Zamani K, Frank R, Fontaine G, Nitenberg A, and Lecarpentier Y. Clin Sci (Lond) 103: 7-13, 2002], and DAP + [0.33 + (heart rate x 0.0012)] PP (Razminia M, Trivedi A, Molnar J, Elbzour M, Guerrero M, Salem Y, Ahmed A, Khosla S, Lubell DL. Catheter Cardiovasc Interv 63: 419-425, 2004). They all provided accurate and precise estimates of MAP [mean bias = -0.2 (SD 2.9), -0.3 (SD 2.7), and 0.1 mmHg (SD 2.9), respectively]. The implications of the geometric mean pressure strictly pertained to the central (not peripheral) level. It was demonstrated that the fractional systolic (SAP/MAP) and diastolic (DAP/MAP) pressures were reciprocal estimates of aortic pulsatility and that the SAP times DAP product matched the total peripheral resistance times cardiac power product. In conclusion, although the previously described thumb-rules applied, the "geometric MAP" appears more valuable as it established a simple mathematical link between the steady and pulsatile component of aortic pressure.

PubMed Disclaimer

Publication types

LinkOut - more resources