Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2005 Jul;34(5):551-8.
doi: 10.1016/j.ijom.2004.10.009.

Comparison of different fixation methods following sagittal split ramus osteotomies using three-dimensional finite elements analysis. Part 1: advancement surgery-posterior loading

Affiliations
Comparative Study

Comparison of different fixation methods following sagittal split ramus osteotomies using three-dimensional finite elements analysis. Part 1: advancement surgery-posterior loading

E Erkmen et al. Int J Oral Maxillofac Surg. 2005 Jul.

Abstract

The purpose of this study was to evaluate the mechanical behavior of different fixation methods used in bilateral sagittal split ramus osteotomy (BSSRO). Part 1 comprises of the results of the analysis for mandibular advancement, four different fixation configurations of six hole fragmentation mini plates with monocortical screws and lag screws and posterior loading conditions in the molar and premolar region. The finite element analysis method (FEA) appears suitable for simulating complex mechanical stress situations in the maxillofacial region. The mechanical behavior of selected lag screws with linear or triangular configuration and double parallel or single oblique six hole mini plates with monocortical screws were compared by FEA after 5 mm BSSRO advancement procedure. Four separate three-dimensional finite element models of the mandible were created to simulate the BSSRO and corresponding fixation methods. These models consisted of 122,717 elements and 25,048 nodes. The mechanical parameters of the materials studied were adopted from the literature or were based on manufacturer's information. 500 N posterior occlusal loads were simulated on the distal segments. The commercial finite element solver MSC Marc software was utilized to calculate the stress fields on both the segments and fixative appliances. It was concluded that the use of 2.0mm lag screws placed in a triangular configuration following the BSSRO advancement surgery provides sufficient stability with any rotational movement and less stress fields at the osteotomy site, when compared with the other rigid fixation methods used in the current study.

PubMed Disclaimer

Publication types

LinkOut - more resources