Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2005 Aug;112(8):1381-7.
doi: 10.1016/j.ophtha.2005.03.010.

Nomogram-based intraocular lens power adjustment after myopic photorefractive keratectomy and LASIK: a new approach

Affiliations
Comparative Study

Nomogram-based intraocular lens power adjustment after myopic photorefractive keratectomy and LASIK: a new approach

Vahid Feiz et al. Ophthalmology. 2005 Aug.

Abstract

Purpose: (1) To evaluate the accuracy of nomogram-based adjustment of intraocular lens (IOL) power to achieve a desired refractive target after cataract surgery in postmyopic LASIK and photorefractive keratectomy (PRK) eyes and (2) to compare the accuracy of the nomogram-based method with the clinical history method.

Design: Multicenter, retrospective, interventional, noncomparative case series.

Subjects: Fourteen patients (19 eyes) after myopic LASIK or PRK with visually significant cataracts.

Intervention: All eyes underwent cataract extraction and posterior chamber intraocular lens implantation. In each case, IOL power was determined with standard keratometry and biometry. Power adjustment was made by use of a theoretical nomogram followed by implantation.

Main outcome measures: (1) Final refraction and spherical equivalent after cataract surgery and (2) deviation of the final spherical equivalent from the refractive target.

Results: After cataract extraction, by use of nomogram adjustment, 63.2% of eyes were within 0.5 D of the intended spherical equivalent, 84.2% were within 1.0 diopter of the intended spherical equivalent, and 100% were within 1.5 D of the intended spherical equivalent. The clinical history method was accurate in predicting the correct IOL power in 37.5% of cases, regardless of whether spectacle or corneal plane refraction was used.

Conclusions: (1) Given the change in spherical equivalent induced by myopic LASIK/PRK, IOL power can be adjusted accurately to avoid undercorrection without the need for the prerefractive surgery corneal power. (2) The nomogram-based method was more accurate than the clinical history method.

PubMed Disclaimer

Publication types

LinkOut - more resources