[Intrathoracic blood volume versus pulmonary artery occlusion pressure as estimators of cardiac preload in critically ill patients]
- PMID: 16075124
- DOI: 10.4067/s0034-98872005000600001
[Intrathoracic blood volume versus pulmonary artery occlusion pressure as estimators of cardiac preload in critically ill patients]
Abstract
Background: Monitoring of cardiac preload by determination of pulmonary artery occlusion pressure (PAOP) has been traditionally used to guide fluid therapy to optimize cardiac output (CO). Since factors such as intrathoracic pressure and ventricular compliance may modify PAOP, volumetric estimators of preload have been developed. The PiCCO system is able to measure CO and intrathoracic blood volume (ITBV) by transpulmonary thermodilution.
Aim: To compare a volumetric (ITBV) versus a pressure (PAOP) determination to accurately estimate cardiac preload in severely ill patients.
Patients and methods: From June 2001 to October 2003, 22 mechanically ventilated patients with hemodynamic instability underwent hemodynamic monitoring with pulmonary artery catheter (PAC) and PiCCO system. ITBV index (ITBVI), PAOP and CI were measured simultaneously by both methods. One hundred thirty eight deltas (D) were obtained from the difference of ITBVI, PAOP, CI-PAC and CI-PiCCO between 6-12 am and 6-12 pm. Linear regression analysis of DITBVI versus Eth CI-PiCCO and Eth PAOP versus DCI-PAC were made.
Results: Mean age of patients was 60.8 +/- 19.4 years. APACHE II was 23.9 +/- 7. Fifteen patients met criteria for acute respiratory distress syndrome (ARDS). Delta ITBVI significantly correlated with DCI-PiCCO (r=0.54; 95% confidence interval = 0.41-0.65; p <0.01). There was no correlation between DPAOP and DCI-PAC.
Conclusion: ITBVI correlated better with CI than PAOP, and therefore it seems to be a more accurate estimator of preload in unstable, mechanically ventilated patients.
Similar articles
-
Preload index: pulmonary artery occlusion pressure versus intrathoracic blood volume monitoring during lung transplantation.Anesth Analg. 2002 Oct;95(4):835-43, table of contents. doi: 10.1097/00000539-200210000-00009. Anesth Analg. 2002. PMID: 12351254 Clinical Trial.
-
Central venous pressure, pulmonary artery occlusion pressure, intrathoracic blood volume, and right ventricular end-diastolic volume as indicators of cardiac preload.J Crit Care. 1996 Dec;11(4):180-8. doi: 10.1016/s0883-9441(96)90029-5. J Crit Care. 1996. PMID: 8977994
-
Comparison between intrathoracic blood volume and cardiac filling pressures in the early phase of hemodynamic instability of patients with sepsis or septic shock.J Crit Care. 1999 Jun;14(2):78-83. doi: 10.1016/s0883-9441(99)90018-7. J Crit Care. 1999. PMID: 10382788
-
[Assessment of volume responsiveness in mechanically ventilated patients].Anaesthesist. 2003 Nov;52(11):1005-7, 1010-3. doi: 10.1007/s00101-003-0600-1. Anaesthesist. 2003. PMID: 14992086 Review. German.
-
Hemodynamic monitoring by transpulmonary thermodilution and pulse contour analysis in critically ill children.Pediatr Crit Care Med. 2011 Jul;12(4):459-66. doi: 10.1097/PCC.0b013e3182070959. Pediatr Crit Care Med. 2011. PMID: 21263372 Review.
Cited by
-
Haemodynamic monitoring in acute heart failure.Heart Fail Rev. 2007 Jun;12(2):105-11. doi: 10.1007/s10741-007-9010-9. Heart Fail Rev. 2007. PMID: 17447139 Review.
Publication types
MeSH terms