Purpose: To evaluate the effect of decentration of a monofocal intraocular lens (IOL) and a refractive multifocal IOL on retinal image quality using a new visual simulation system.
Methods: Using a new visual simulation system, we performed visual simulation of a monofocal and a multifocal IOL at 5, 4, 3, 2, 1, and 0.4 m with several decentered IOL positions from 0 to 1.0 mm through a 3- or 4-mm aperture using Landolt visual acuity (VA) charts. The VA was estimated under each condition from the simulated retinal image.
Results: With a monofocal IOL, the image was affected minimally by decentration at 4 and 5 m; at 2 and 3 m, the image contrast decreased slightly with increased decentration. With the multifocal IOL, some loss of image contrast developed at all distances compared with the monofocal IOL; however, the images of the Landolt's rings were still recognizable under all conditions.
Conclusions: Our results suggest that up to 1.0 mm of decentration of a monofocal and multifocal IOL would not greatly affect the retinal image quality.
(c) Japanese Ophthalmological Society 2005.
Similar articles
-
Correlation between pupillary size and intraocular lens decentration and visual acuity of a zonal-progressive multifocal lens and a monofocal lens.Ophthalmology. 2001 Nov;108(11):2011-7. doi: 10.1016/s0161-6420(01)00756-4. Ophthalmology. 2001. PMID: 11713071
-
All-distance visual acuity and contrast visual acuity in eyes with a refractive multifocal intraocular lens with minimal added power.Ophthalmology. 2009 Mar;116(3):401-8. doi: 10.1016/j.ophtha.2008.09.052. Epub 2009 Jan 18. Ophthalmology. 2009. PMID: 19152978
-
One-year outcomes with new-generation multifocal intraocular lenses.Ophthalmology. 2008 Sep;115(9):1508-16. doi: 10.1016/j.ophtha.2008.04.017. Epub 2008 Jun 5. Ophthalmology. 2008. PMID: 18538402 Clinical Trial.
-
[Multifocal intraocular lenses--an assessment of current status].Klin Monbl Augenheilkd. 1993 Jul;203(1):19-33. doi: 10.1055/s-2008-1045645. Klin Monbl Augenheilkd. 1993. PMID: 8411889 Review. German.
-
Magnification and visual acuity in refractive surgery.Arch Ophthalmol. 1993 Oct;111(10):1335-42. doi: 10.1001/archopht.1993.01090100043025. Arch Ophthalmol. 1993. PMID: 8216013 Review.
Cited by
-
Quantification of ghosting produced with presbyopic contact lens correction.Eye Contact Lens. 2012 Jul;38(4):252-9. doi: 10.1097/ICL.0b013e31825aa879. Eye Contact Lens. 2012. PMID: 22735627 Free PMC article.
-
Influence of tilt and decentration of scleral-sutured intraocular lens on ocular higher-order wavefront aberration.Br J Ophthalmol. 2007 Feb;91(2):185-8. doi: 10.1136/bjo.2006.099945. Epub 2006 Aug 16. Br J Ophthalmol. 2007. PMID: 16914469 Free PMC article.
-
A Comparative Analysis of the Effects of Misaligning Different Trifocal Intraocular Lenses.J Clin Med. 2024 Dec 31;14(1):187. doi: 10.3390/jcm14010187. J Clin Med. 2024. PMID: 39797271 Free PMC article.
References
MeSH terms
LinkOut - more resources
Full Text Sources
Medical