Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Case Reports
. 2005 Jul-Aug;29(4):281-6.
doi: 10.1007/s00266-004-0102-9. Epub 2005 Jul 19.

Analysis of laser lipolysis effects on human tissue samples obtained from liposuction

Affiliations
Case Reports

Analysis of laser lipolysis effects on human tissue samples obtained from liposuction

Ana Zulmira E D Badin et al. Aesthetic Plast Surg. 2005 Jul-Aug.

Abstract

Background: The use of the neodymium: yttrium-aluminum-garnet (Nd:YAG) laser as an auxiliary tool for lipoplasty has refined the traditional technique. The primary limitation of the traditional technique-large volume blood loss-is addressed by the use of the Nd:YAG laser. This report describe's the technique of laser- assisted liposuction, then reviews and compares the histologic and morphometric effects with those of the traditional method.

Methods: The Nd:YAG laser was used to produce the desired injury to the adipose tissue after sufficient contact. Laser lipolysis was performed on the patient's right flank in two different areas, with the application of 1,000 and 3,000 J of accumulated energy (in), respectively. Subsequently, another cannula was introduced to suction the liquid content obtained by laser lipolysis. This tissue product was sent to the pathology laboratory for morphologic and morphometric analysis, and for comparison with material obtained from traditional lipoplasty performed on the left flank of the same patient.

Results: The histopathologic examination of adipose tissue after laser lipolysis showed cell swelling and less bleeding, as compared with the traditional method. The morphometric analysis showed that the mean diameter of the major adipocyte was 95.69 microm with laser lipolysis using 1,000 J (in), 82.63 microm using 3,000 J (in), and 84.54 microm with the traditional method

Conclusions: The traditional method produced less reversible cellular damage (swelling) than laser lipolysis using 1,000 J (in). The area receiving 3,000 J (in) showed major irreversible damage (cytoplasmatic retraction and disruption of membranes). For this reason, the mean diameter of the adipocyte was less.

PubMed Disclaimer

Publication types

LinkOut - more resources