Training and calibration improve inter-reader reliability of joint damage assessment using magnetic resonance image scoring and computerized erosion volume measurement
- PMID: 16078319
Training and calibration improve inter-reader reliability of joint damage assessment using magnetic resonance image scoring and computerized erosion volume measurement
Abstract
Objective: To assess the inter-reader reliability of 3 rheumatologist readers before and after training using 2 methods of assessment: magnetic resonance imaging (MRI) computerized erosion volume assessment and MRI scoring using the OMERACT-5 Rheumatoid Arthritis MRI Score (OM-5 RAMRIS) criteria.
Methods: Erosion volumes were measured in 10 patients [5 wrist and 5 metacarpophalangeal (MCP) joint studies] with rheumatoid arthritis. Erosion scores were derived from this group and 8 additional subjects to provide a total of 18 subjects (10 wrist and 8 MCP joint studies) with MRI scores for comparison. Subjects were selected from existing MRI databases to provide a spectrum of joint damage for assessment. Initial reading was undertaken after the 2 inexperienced readers were provided with instructions regarding OSIRIS computer software and definitions of the OMERACT score; no other formal training was undertaken. One month after the initial reading, the 2 inexperienced readers undertook a 3 hour training session and all 3 readers then took part in 2 subsequent 2 hour calibration sessions. Each reader then reread the original MRI studies using the computerized erosion volume method and the OMERACT MRI RA score. The interval between the baseline and post-training reading was 2 months. All reading was undertaken on a computer workstation and readers were blinded to other readers' results.
Results: For the wrist MRI studies, inter-reader agreement improved considerably after training for both the computerized MRI volume method and the OMERACT MRI score [intraclass correlation coefficients (ICC) 0.21 and 0.46, respectively, pre-training; 0.92 and 0.85 post-training]. The correlation between all readers' scores and volumes was excellent at baseline and post-training. For the MCP joint studies, inter-reader agreement was moderate at baseline for the erosion volume and score (ICC 0.51 and 0.61). While there was some improvement in agreement post-training for the scoring method (ICC 0.75), there was no significant improvement for the erosion volumes (ICC 0.58).
Conclusion: Overall, inter-reader agreement for erosion scoring and volume measurement was higher for the wrist joint. The lack of improvement in the MCP joint region for the erosion volume measurements appears to relate primarily to difficulties in estimating the erosion border in the proximal MCP joints using the manual outlining tool. This limits the usefulness of erosion volume measurements in this joint region.
Similar articles
-
OMERACT Rheumatoid Arthritis Magnetic Resonance Imaging Studies. Exercise 5: an international multicenter reliability study using computerized MRI erosion volume measurements.J Rheumatol. 2003 Jun;30(6):1380-4. J Rheumatol. 2003. PMID: 12784421
-
Computerized measurement of magnetic resonance imaging erosion volumes in patients with rheumatoid arthritis: a comparison with existing magnetic resonance imaging scoring systems and standard clinical outcome measures.Arthritis Rheum. 2003 Mar;48(3):614-24. doi: 10.1002/art.10820. Arthritis Rheum. 2003. PMID: 12632412
-
OMERACT Rheumatoid Arthritis Magnetic Resonance Imaging Studies. Exercise 3: an international multicenter reliability study using the RA-MRI Score.J Rheumatol. 2003 Jun;30(6):1366-75. J Rheumatol. 2003. PMID: 12784419
-
OMERACT Rheumatoid Arthritis Magnetic Resonance Imaging Studies. Summary of OMERACT 6 MR Imaging Module.J Rheumatol. 2003 Jun;30(6):1387-92. J Rheumatol. 2003. PMID: 12784423 Review.
-
OMERACT Rheumatoid Arthritis Magnetic Resonance Imaging Studies. Core set of MRI acquisitions, joint pathology definitions, and the OMERACT RA-MRI scoring system.J Rheumatol. 2003 Jun;30(6):1385-6. J Rheumatol. 2003. PMID: 12784422 Review.
Cited by
-
MRI of the wrist in juvenile idiopathic arthritis: proposal of a paediatric synovitis score by a consensus of an international working group. Results of a multicentre reliability study.Pediatr Radiol. 2012 Sep;42(9):1047-55. doi: 10.1007/s00247-012-2392-4. Epub 2012 Jul 26. Pediatr Radiol. 2012. PMID: 22832863
-
Registration-Based Morphometry for Shape Analysis of the Bones of the Human Wrist.IEEE Trans Med Imaging. 2016 Feb;35(2):416-26. doi: 10.1109/TMI.2015.2476817. IEEE Trans Med Imaging. 2016. PMID: 26353369 Free PMC article.
-
A modification of the Omeract RA MRI score for erosions for use with an extremity MRI system with reduced field of view.Ann Rheum Dis. 2007 Dec;66(12):1669-71. doi: 10.1136/ard.2007.072561. Epub 2007 Jul 6. Ann Rheum Dis. 2007. PMID: 17616555 Free PMC article.
-
Atlas of the OMERACT Heel Enthesitis MRI Scoring System (HEMRIS).RMD Open. 2020 Feb;6(1):e001150. doi: 10.1136/rmdopen-2019-001150. Epub 2020 Feb 11. RMD Open. 2020. PMID: 32568094 Free PMC article.
-
The impact of MRI on the clinical management of inflammatory arthritides.Skeletal Radiol. 2011 Sep;40(9):1153-73. doi: 10.1007/s00256-011-1204-5. Epub 2011 Aug 17. Skeletal Radiol. 2011. PMID: 21847747 Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous