[Cutaneous and subcutaneous blood flow measurement in rabbit's ear by epicutaneous diffusion of xenon 133. Influence of the arteriovenous anastomosis]
- PMID: 160819
[Cutaneous and subcutaneous blood flow measurement in rabbit's ear by epicutaneous diffusion of xenon 133. Influence of the arteriovenous anastomosis]
Abstract
The cutaneous and subcutaneous blood flow measurement by a diffusible inert gas concerns theorically capillary nutritional flow. In clinical routine, where pathological openning of arteriovenous anastomosis is suspected, the blood flows measured by Xenon technic are often increased. The function of the shunts are displayed on the epuration curve obtained on a region where there are numerous: rabbit's ear.
Similar articles
-
Cutaneous arteriovenous anastomoses present in the tail but absent from the ear of the rat.J Anat. 1977 Nov;124(Pt 2):355-8. J Anat. 1977. PMID: 591433 Free PMC article.
-
Differential thermal influences on skin blood flow through capillaries and arteriovenous anastomoses, and on sympathetic activity.Bibl Anat. 1977;(16 Pt 2):189-91. Bibl Anat. 1977. PMID: 603511 No abstract available.
-
[Study of skin microcirculation by epicutaneous diffusion of 133 xenon].C R Seances Soc Biol Fil. 1977;171(2):340-4. C R Seances Soc Biol Fil. 1977. PMID: 142552 French.
-
Cutaneous blood flow and tissue blood exchange.Adv Biol Skin. 1972;12:191-205. Adv Biol Skin. 1972. PMID: 4579192 Review. No abstract available.
-
Neural regulation of cutaneous circulation.Adv Biol Skin. 1972;12:207-33. Adv Biol Skin. 1972. PMID: 4579194 Review. No abstract available.