Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2005 Aug;18(8):779-88.
doi: 10.1016/j.echo.2004.12.015.

Improved semiautomated quantification of left ventricular volumes and ejection fraction using 3-dimensional echocardiography with a full matrix-array transducer: comparison with magnetic resonance imaging

Affiliations
Comparative Study

Improved semiautomated quantification of left ventricular volumes and ejection fraction using 3-dimensional echocardiography with a full matrix-array transducer: comparison with magnetic resonance imaging

Enrico G Caiani et al. J Am Soc Echocardiogr. 2005 Aug.

Erratum in

  • J Am Soc Echocardiogr. 2011 Oct;24(10):1155. Gutierrez, Juan Luis [corrected to Gutiérrez-Chico, Juan Luis]

Abstract

Our goals were to: (1) develop a technique for 3-dimensional (3D) direct, model-independent quantitative assessment of left ventricular (LV) volume and ejection fraction based on semiautomated detection of LV endocardial surface from transthoracic near real-time full matrix-array 3D echocardiographic (FM3DE) imaging; (2) evaluate the accuracy of LV volumes obtained with this technique, using cardiac magnetic resonance imaging (MRI) measurements as the reference for comparison; and (3) determine the effects of contrast enhancement on the accuracy of FM3DE measurements. A total of 46 patients underwent 2-dimensional echocardiography, FM3DE, and cardiac MRI. End-diastolic volume, end-systolic volume, and ejection fraction were derived from endocardial borders manually traced from 2-dimensional echocardiographic images and from semiautomatically detected LV cavity from FM3DE data. In 14 patients, FM3DE was also acquired with contrast. All measurements were compared with MRI values using linear regression and Bland-Altman analyses. FM3DE was feasible in 44 of 46 patients with LV volumes < 345 mL. LV volumes and ejection fraction computed from FM3DE resulted in higher levels of agreement with MRI than conventional 2-dimensional echocardiography, with lower interobserver variability. With contrast enhancement, FM3DE significantly underestimated LV volumes and showed increased interobserver variability. Semiautomated LV endocardial surface detection from FM3DE images is feasible and results in fast and accurate assessment of LV function.

PubMed Disclaimer

Publication types

LinkOut - more resources