MR-guided endovascular interventions: device visualization, tracking, navigation, clinical applications, and safety aspects
- PMID: 16084411
- DOI: 10.1016/j.mric.2005.04.004
MR-guided endovascular interventions: device visualization, tracking, navigation, clinical applications, and safety aspects
Abstract
Reliable visualization and tracking are essential for guiding endovascular devices within blood vessels. The most commonly used methods are susceptibility artifact-based tracking that relies on the artifact created within the image by the device and microcoil- or antenna-based tracking that uses the high signal generated by small MR endovascular receive coils when the transmit coil emits a nonselective radiofrequency pulse. To date, the use of endovascular MR guidance techniques has primarily been confined to animal experiments. There are only a few reports on MR-guided endovascular applications in patients. Therefore, access to the patient within the scanner, dedicated devices, and safety issues remain major challenges. To face these challenges, attention from all radiologists, especially interventional radiologists, is required to make MR-guided endovascular procedures a clinical reality.
Similar articles
-
Visualization, tracking, and navigation of instruments for magnetic resonance imaging-guided endovascular procedures.Top Magn Reson Imaging. 2000 Jun;11(3):163-72. doi: 10.1097/00002142-200006000-00002. Top Magn Reson Imaging. 2000. PMID: 11145208 Review.
-
MR-guided intravascular interventions: techniques and applications.J Magn Reson Imaging. 2008 Feb;27(2):326-38. doi: 10.1002/jmri.21271. J Magn Reson Imaging. 2008. PMID: 18219686 Review.
-
Magnetic resonance imaging-guided renal artery stent placement in a Swine model: comparison of two tracking techniques.Acta Radiol. 2009 Jan;50(1):21-7. doi: 10.1080/02841850802570553. Acta Radiol. 2009. PMID: 19101851
-
MR-guided biopsy: a review of current techniques and applications.J Magn Reson Imaging. 2008 Feb;27(2):311-25. doi: 10.1002/jmri.21270. J Magn Reson Imaging. 2008. PMID: 18219685 Review.
-
[Magnetic resonance imaging-guided endovascular interventions].Rofo. 2007 Apr;179(4):355-64. doi: 10.1055/s-2007-962930. Rofo. 2007. PMID: 17385130 Review. German.
Cited by
-
Stem cell therapy: MRI guidance and monitoring.J Magn Reson Imaging. 2008 Feb;27(2):299-310. doi: 10.1002/jmri.21263. J Magn Reson Imaging. 2008. PMID: 18219684 Free PMC article. Review.
-
Safe guidewire visualization using the modes of a PTx transmit array MR system.Magn Reson Med. 2020 Jun;83(6):2343-2355. doi: 10.1002/mrm.28069. Epub 2019 Nov 13. Magn Reson Med. 2020. PMID: 31722119 Free PMC article.
-
How AI and Robotics Will Advance Interventional Radiology: Narrative Review and Future Perspectives.Diagnostics (Basel). 2024 Jun 29;14(13):1393. doi: 10.3390/diagnostics14131393. Diagnostics (Basel). 2024. PMID: 39001283 Free PMC article. Review.
-
MR-guided endovascular interventions: a comprehensive review on techniques and applications.Eur Radiol. 2008 Apr;18(4):645-57. doi: 10.1007/s00330-007-0818-4. Epub 2007 Dec 11. Eur Radiol. 2008. PMID: 18071710 Review.
-
The performance of interventional loopless MRI antennae at higher magnetic field strengths.Med Phys. 2008 May;35(5):1995-2006. doi: 10.1118/1.2905027. Med Phys. 2008. PMID: 18561676 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources