. 2005 Jul-Aug;12(4):401-9.
doi: 10.1016/j.nuclcard.2005.04.010.

Contributions of subdiaphragmatic activity, attenuation, and diaphragmatic motion to inferior wall artifact in attenuation-corrected Tc-99m myocardial perfusion SPECT

Affiliations

Contributions of subdiaphragmatic activity, attenuation, and diaphragmatic motion to inferior wall artifact in attenuation-corrected Tc-99m myocardial perfusion SPECT

Alexander G Pitman et al. J Nucl Cardiol. 2005 Jul-Aug.

Abstract

Background: Subdiaphragmatic activity and diaphragmatic motion both contribute to inferior wall artifacts in technetium 99m myocardial perfusion single photon emission computed tomography (SPECT).

Methods and results: We used an anthropomorphic phantom with ventricular wall activity, liver/spleen inserts containing variable Tc-99m activity, and variable vertical (diaphragmatic) motion amplitude. SPECT and transmission scans were obtained on a GE Optima NX camera. Data were processed by use of filtered backprojection or attenuation correction (AC). Resulting myocardial activity maps were analyzed with standardized inferior-anterior and anterior-lateral wall ratios. At a subdiaphragmatic-myocardial activity ratio of 0.5:1, inferior wall attenuation predominates, producing a cold artifact. AC corrects inferior wall activity to the level of the anterior wall irrespective of diaphragmatic motion. At a subdiaphragmatic-myocardial activity ratio of 1:1, inferior wall counts vary widely depending on the proximity of subdiaphragmatic activity to the ventricle. With increasing diaphragmatic amplitude, the overlap of subdiaphragmatic activity and inferior wall worsens, leading to a complex mixture of cold and hot artifacts, not corrected by AC.

Conclusions: Concentration and proximity of subdiaphragmatic Tc-99m activity relative to myocardium comprise a major factor in the nature and severity of inferior wall artifacts. If the subdiaphragmatic Tc-99m concentration is equivalent to that in the myocardium, complex, potentially uninterpretable hot and cold inferior wall artifacts are produced.

PubMed Disclaimer

References

    1. Radiology. 1998 Nov;209(2):483-9 - PubMed
    1. Eur J Nucl Med. 1997 Sep;24(9):1107-14 - PubMed
    1. Eur J Nucl Med. 1996 Oct;23(10):1300-8 - PubMed
    1. J Nucl Med. 1994 Feb;35(2):356-9 - PubMed
    1. J Nucl Med. 2002 Sep;43(9):1259-67 - PubMed

Publication types

MeSH terms

LinkOut - more resources