Electromagnetic perspective on the operation of RF coils at 1.5-11.7 Tesla
- PMID: 16088934
- DOI: 10.1002/mrm.20596
Electromagnetic perspective on the operation of RF coils at 1.5-11.7 Tesla
Abstract
In this work experimental and numerical studies of the MR signal were performed at frequencies ranging from 64 MHz to 485 MHz, utilizing three different MRI coils: a single-strut transverse electromagnetic (TEM)-based coil, a TEM resonator, and a high-pass birdcage coil. The experimental analyses were conducted using 1.5 and 8 Tesla whole-body systems and volume RF head coils. The simulation data were obtained utilizing an in-house-developed finite difference time domain (FDTD) model. Pertinent data from the numerical and experimental setups were compared, and a remarkable agreement between the two methods was found that clearly demonstrates the effectiveness of the FDTD method when it is applied rigorously. The numerical and experimental studies demonstrate the complexity of the electromagnetic (EM) fields and their role in the MR signal. These studies also reveal unique similarities and differences between the transmit and receive field distributions at various field strengths. Finally, for ultra high-field operations, it was demonstrated mathematically, numerically, and experimentally that highly asymmetric inhomogeneous images can be acquired even for linear excitation, symmetrical load geometries, and symmetrical load positioning within the coil.
Copyright (c) 2005 Wiley-Liss, Inc.
Similar articles
-
In-depth study of the electromagnetics of ultrahigh-field MRI.NMR Biomed. 2007 Feb;20(1):58-68. doi: 10.1002/nbm.1094. NMR Biomed. 2007. PMID: 17006885
-
Black body and transverse electromagnetic resonators operating at 340 MHz: volume RF coils for ultra high field MRI.J Comput Assist Tomogr. 1999 Nov-Dec;23(6):879-90. doi: 10.1097/00004728-199911000-00011. J Comput Assist Tomogr. 1999. PMID: 10589562
-
B1 field, SAR, and SNR comparisons for birdcage, TEM, and microstrip coils at 7T.J Magn Reson Imaging. 2006 Aug;24(2):439-43. doi: 10.1002/jmri.20635. J Magn Reson Imaging. 2006. PMID: 16786582
-
Radiofrequency microcoils for magnetic resonance imaging and spectroscopy.J Magn Reson. 2013 Apr;229:55-66. doi: 10.1016/j.jmr.2012.10.004. Epub 2012 Oct 26. J Magn Reson. 2013. PMID: 23142002 Review.
-
Ultra-high field MRI: parallel-transmit arrays and RF pulse design.Phys Med Biol. 2023 Jan 18;68(2). doi: 10.1088/1361-6560/aca4b7. Phys Med Biol. 2023. PMID: 36410046 Review.
Cited by
-
Stepped impedance resonators for high-field magnetic resonance imaging.IEEE Trans Biomed Eng. 2014 Feb;61(2):327-33. doi: 10.1109/TBME.2013.2250973. IEEE Trans Biomed Eng. 2014. PMID: 23508243 Free PMC article.
-
Ultra-high-field RF coil development for evaluating upper extremity imaging applications.NMR Biomed. 2016 Dec;29(12):1768-1779. doi: 10.1002/nbm.3582. Epub 2016 Nov 3. NMR Biomed. 2016. PMID: 27809383 Free PMC article.
-
RF shimming strategy for an open 60-channel RF transmit 7T MRI head coil for routine use on the single transmit mode.Magn Reson Med. 2025 Oct;94(4):1804-1816. doi: 10.1002/mrm.30563. Epub 2025 May 20. Magn Reson Med. 2025. PMID: 40391665 Free PMC article.
-
Understanding and manipulating the RF fields at high field MRI.NMR Biomed. 2009 Nov;22(9):927-36. doi: 10.1002/nbm.1406. NMR Biomed. 2009. PMID: 19621335 Free PMC article.
-
RF Head Coil Design with Improved RF Magnetic Near-Fields Uniformity for Magnetic Resonance Imaging (MRI) Systems.IEEE Trans Microw Theory Tech. 2014 Aug;62(8):1784-1789. doi: 10.1109/tmtt.2014.2331621. IEEE Trans Microw Theory Tech. 2014. PMID: 25892746 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical