Early clinical results of St. Jude Medical Symmetry aortic connector
- PMID: 16094513
- DOI: 10.1007/s10047-005-0293-0
Early clinical results of St. Jude Medical Symmetry aortic connector
Abstract
An automated anastomosis device named St. Jude Medical symmetry aortic connector has been used worldwide for off-pump coronary artery bypass grafting. However, early graft obstruction was recently reported, and its predictors should be clarified. From April 2002 to March 2004, 38 patients in our institution underwent off-pump coronary artery bypass grafting using the St. Jude Medical Symmetry aortic connector for saphenous vein graft (SVG) procedures; measurement of intraoperative graft flow and postoperative coronary angiography was performed. Early SVG events occurred in 9 (24%) patients: 8 occlusion cases and 1 case of stenosis. Predictors of early SVG events were assessed from a comparative study. Univariate logistic regression identified hyperlipidemia as the only significant predictor of early SVG events (P = 0.02, odds ratio 7.78). Lower SVG flow rate and poor ejection fraction did not show statistical significance (P = 0.09, odds ratio 1.09 and P = 0.09, odds ratio 0.96). The SVG event rate was much higher for the left circumflex branch compared with other locations (31% vs. 9%, P = 0.03) and decreased with increasing aortic connector size (small, 32%; median, 14%; large, 0%). Multivariate analysis did not identify a predictor of SVG events. The aortic connector is associated with a high incidence of early SVG events. Patients should be cautiously selected and the procedure should not be used for left anterior descending coronary artery or culprit lesions.
Similar articles
-
Technique for using the St. Jude aortic connector in anastomosis with a composite graft of saphenous vein and radial artery.Ann Thorac Cardiovasc Surg. 2005 Aug;11(4):281-3. Ann Thorac Cardiovasc Surg. 2005. PMID: 16148881
-
Early and midterm patency of the proximal anastomoses of saphenous vein grafts made with a Symmetry Aortic Connector System.J Thorac Cardiovasc Surg. 2005 Oct;130(4):1028-31. doi: 10.1016/j.jtcvs.2005.05.026. J Thorac Cardiovasc Surg. 2005. PMID: 16214515
-
The St Jude Medical symmetry aortic connector system for proximal vein graft anastomoses in coronary artery bypass grafting.J Thorac Cardiovasc Surg. 2002 Apr;123(4):777-82. doi: 10.1067/mtc.2002.119695. J Thorac Cardiovasc Surg. 2002. PMID: 11986606
-
Minimizing aortic manipulation during OPCAB using the symmetry aortic connector system for proximal vein graft anastomoses.Ann Thorac Surg. 2001 Sep;72(3):S995-8. doi: 10.1016/s0003-4975(01)02965-4. Ann Thorac Surg. 2001. PMID: 11565735
-
Early ostial saphenous vein graft stenosis associated with the use of Symmetry sutureless aortic proximal anastomosis device: successful percutaneous revascularization.Catheter Cardiovasc Interv. 2004 Jun;62(2):203-8. doi: 10.1002/ccd.20048. Catheter Cardiovasc Interv. 2004. PMID: 15170712 Review.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous