The reliability of short-term measurements of heart rate variability
- PMID: 16098384
- DOI: 10.1016/j.ijcard.2004.09.013
The reliability of short-term measurements of heart rate variability
Abstract
Short-term assessment of heart rate variability (HRV) is a non-invasive technique to examine ANS function. Within the literature, HRV is commonly referred to as a reliable measurement technique. The aim of this review was to assess the accuracy of this description based upon a comprehensive review of the available data concerning reliability of short-term HRV measures. Reviewing only studies using appropriate statistical analyses, it was determined that reliability coefficients for HRV measures were highly varied. Coefficients of variation ranged from <1% to >100%. Similar variation was found in studies using the intraclass correlation coefficient values, and limits of agreement. Reliability coefficients reported displayed some distinct patterns. Firstly, where measurements were made during interventions such as tilt or pharmacological stimulation, reliability was poorer than when HRV was measured at rest. Secondly, clinical populations displayed poorer reliability than healthy subjects. There was little effect of test-retest duration on reliability and although no single HRV measurement appeared less reliable than another, there was evidence that optimal data collection conditions for specific frequency domain measures exist. Describing HRV as a reliable measurement technique appears to be a gross oversimplification, as results of reliability studies are heterogeneous, and dependent on a number of factors. Further studies are required, particularly in clinical populations to assess HRV reliability. Authors should refer to coefficients from similar populations measured under similar conditions when making future sample size calculations.
Similar articles
-
Heart rate variability measures: a fresh look at reliability.Clin Sci (Lond). 2007 Aug;113(3):131-40. doi: 10.1042/CS20070055. Clin Sci (Lond). 2007. PMID: 17381425
-
Assessing nonlinear properties of heart rate variability from short-term recordings: are these measurements reliable?Physiol Meas. 2007 Sep;28(9):1067-77. doi: 10.1088/0967-3334/28/9/008. Epub 2007 Aug 21. Physiol Meas. 2007. PMID: 17827654
-
Short-term testing of heart rate variability in heart-transplanted children: equal to 24-h ECG recordings?Clin Transplant. 2006 Jul-Aug;20(4):438-42. doi: 10.1111/j.1399-0012.2006.00502.x. Clin Transplant. 2006. PMID: 16842518
-
[Heart rate variability and physical exercise. Current status].Herz. 2006 Sep;31(6):544-52. doi: 10.1007/s00059-006-2855-1. Herz. 2006. PMID: 17036185 Review. German.
-
The role of heart rate variability in prognosis for different modes of death in chronic heart failure.Pacing Clin Electrophysiol. 2006 Aug;29(8):892-904. doi: 10.1111/j.1540-8159.2006.00457.x. Pacing Clin Electrophysiol. 2006. PMID: 16923007 Review.
Cited by
-
Reduction of heart rate variability after colorectal resections.Langenbecks Arch Surg. 2012 Jun;397(5):793-9. doi: 10.1007/s00423-012-0903-2. Epub 2012 Jan 17. Langenbecks Arch Surg. 2012. PMID: 22249435
-
Feasibility, Reliability and Predictive Value Of In-Ambulance Heart Rate Variability Registration.PLoS One. 2016 May 4;11(5):e0154834. doi: 10.1371/journal.pone.0154834. eCollection 2016. PLoS One. 2016. PMID: 27144492 Free PMC article.
-
Intra- and Inter-Rater Reliability of Linear and Nonlinear Measures of Short-Term Heart Rate Variability Following Combat-Related Traumatic Injury.Ann Noninvasive Electrocardiol. 2024 Sep;29(5):e70008. doi: 10.1111/anec.70008. Ann Noninvasive Electrocardiol. 2024. PMID: 39194165 Free PMC article.
-
Reproducibility and validity of heart rate variability and respiration rate measurements in participants with prolonged fatigue complaints.Int Arch Occup Environ Health. 2009 Apr;82(5):623-30. doi: 10.1007/s00420-008-0391-4. Epub 2008 Nov 26. Int Arch Occup Environ Health. 2009. PMID: 19034486
-
Reproducibility for Heart Rate Variability Analysis during 6-Min Walk Test in Patients with Heart Failure and Agreement between Devices.PLoS One. 2016 Dec 9;11(12):e0167407. doi: 10.1371/journal.pone.0167407. eCollection 2016. PLoS One. 2016. PMID: 27936043 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources