Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2006 Mar;27(7):1035-42.
doi: 10.1016/j.biomaterials.2005.07.003. Epub 2005 Aug 10.

The effect of high outflow permeability in asymmetric poly(dl-lactic acid-co-glycolic acid) conduits for peripheral nerve regeneration

Affiliations
Comparative Study

The effect of high outflow permeability in asymmetric poly(dl-lactic acid-co-glycolic acid) conduits for peripheral nerve regeneration

Chen-Jung Chang et al. Biomaterials. 2006 Mar.

Abstract

This study attempted to accelerate the peripheral nerve regeneration, using the high outflow rate of asymmetric poly(dl-lactic acid-co-glycolic acid) (PLGA) nerve conduits. Asymmetric PLGA nerve conduits of monomer ratio 85/15 were prepared by immersion-precipitation method to serve as possible materials. In this study, mandrels were immersed into a 20% (wt/wt) of PLGA/1,4-dioxane solution and precipitated in a non-solvent bath followed by freeze-drying. Different concentrations of isopropyl alcohol (95%, 40% and 20%) were used as precipitation baths where non-asymmetric (95%) and asymmetric (40% and 20%) conduits could easily form. The asymmetric nerve conduits that consisted of macrovoids on the outer layer, and interconnected micropores in the inner sublayer, possessed characters of larger outflow rate than inflow rate. The asymmetric conduits were implanted to 10mm right sciatic nerve defects in rats. Autografts, silicone and non-asymmetric PLGA conduits were performed as the control and the contrast groups. Implanted graft specimens of all groups were harvested for histological analysis at 4 and 6 weeks following surgery. The asymmetric PLGA conduits maintained a stable supporting structure and inhibited exogenous cells invasion during entire regeneration process. Asymmetric PLGA conduits were found to have statistically greater number of regenerated axons at the midconduit and distal nerve site of implanted grafts, as compared to the silicone and non-asymmetric groups at 4 and 6 weeks. Of interest was that the results of 4 weeks in asymmetric groups were better than the non-asymmetric groups at 6 weeks in number of axons. According to the results of permeability, the asymmetric structure in the conduit wall seemed to enhance the removal of the blockage of the waste drain from the inner inflamed wound in the early stage, which may have improved the efficacy of the peripheral nerve regeneration. The asymmetric structure could be adequately employed in the future as optimal nerve conduits in peripheral nerve regeneration.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources