Accuracy evaluation of direct navigation with an isocentric 3D rotational X-ray system
- PMID: 16099196
- DOI: 10.1016/j.media.2005.04.012
Accuracy evaluation of direct navigation with an isocentric 3D rotational X-ray system
Abstract
Minimally invasive interventions are often performed under fluoroscopic guidance. Drawbacks of fluoroscopic guidance are the fact that the presented images are 2D projections and that both the patient and the clinician are exposed to radiation. Image-guided navigation using pre-interventionally acquired 3D MR or CT data is an alternative. However, this often requires invasive anatomical landmark-based, marker-based or surface-based image-to-patient registration. In this paper, a coupling between an image-guided navigation system and an intraoperative C-arm X-ray device with 3D imaging capabilities (3D rotational X-ray (3DRX) system) that enables direct navigation without invasive image-to-patient registration on 3DRX volumes, is described and evaluated. The coupling is established in a one-time preoperative calibration procedure. The individual steps in the registration procedure are explained and evaluated. The acquired navigation accuracy using this coupling is approximately one millimeter.
Similar articles
-
3D/2D image registration: the impact of X-ray views and their number.Med Image Comput Comput Assist Interv. 2007;10(Pt 1):450-7. Med Image Comput Comput Assist Interv. 2007. PMID: 18051090
-
Direct navigation on 3D rotational x-ray data acquired with a mobile propeller C-arm: accuracy and application in functional endoscopic sinus surgery.Phys Med Biol. 2005 Dec 21;50(24):5769-81. doi: 10.1088/0031-9155/50/24/001. Epub 2005 Dec 1. Phys Med Biol. 2005. PMID: 16333154
-
Respiratory motion compensation by model-based catheter tracking during EP procedures.Med Image Anal. 2010 Oct;14(5):695-706. doi: 10.1016/j.media.2010.05.006. Epub 2010 Jun 10. Med Image Anal. 2010. PMID: 20579931
-
Which navigation when?Injury. 2004 Jun;35 Suppl 1:S-A30-4. doi: 10.1016/j.injury.2004.05.008. Injury. 2004. PMID: 15183701 Review.
-
[Navigation systems for image-guided therapy: A review].Rofo. 2001 Sep;173(9):777-84. doi: 10.1055/s-2001-16975. Rofo. 2001. PMID: 11582555 Review. German.
Cited by
-
Calibration of RGBD camera and cone-beam CT for 3D intra-operative mixed reality visualization.Int J Comput Assist Radiol Surg. 2016 Jun;11(6):967-75. doi: 10.1007/s11548-016-1396-1. Epub 2016 Apr 8. Int J Comput Assist Radiol Surg. 2016. PMID: 27059022
-
Co-localized augmented human and X-ray observers in collaborative surgical ecosystem.Int J Comput Assist Radiol Surg. 2019 Sep;14(9):1553-1563. doi: 10.1007/s11548-019-02035-8. Epub 2019 Jul 26. Int J Comput Assist Radiol Surg. 2019. PMID: 31350704
-
Accuracy and Safety in Pedicle Screw Placement in the Thoracic and Lumbar Spines : Comparison Study between Conventional C-Arm Fluoroscopy and Navigation Coupled with O-Arm® Guided Methods.J Korean Neurosurg Soc. 2012 Sep;52(3):204-9. doi: 10.3340/jkns.2012.52.3.204. Epub 2012 Sep 30. J Korean Neurosurg Soc. 2012. PMID: 23115662 Free PMC article.
-
An on-board surgical tracking and video augmentation system for C-arm image guidance.Int J Comput Assist Radiol Surg. 2012 Sep;7(5):647-65. doi: 10.1007/s11548-012-0682-9. Epub 2012 Apr 27. Int J Comput Assist Radiol Surg. 2012. PMID: 22539008 Free PMC article.
-
Unilateral C1 Lateral Mass and C2 Pedicle Screw Fixation for Atlantoaxial Instability in Rheumatoid Arthritis Patients: Comparison with the Bilateral Method.J Korean Neurosurg Soc. 2015 Jun;57(6):460-4. doi: 10.3340/jkns.2015.57.6.460. Epub 2015 Jun 30. J Korean Neurosurg Soc. 2015. PMID: 26180616 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical