Treatment of type II endoleaks with a novel polyurethane thrombogenic foam: induction of endoleak thrombosis and elimination of intra-aneurysmal pressure in the canine model
- PMID: 16102634
- DOI: 10.1016/j.jvs.2005.04.043
Treatment of type II endoleaks with a novel polyurethane thrombogenic foam: induction of endoleak thrombosis and elimination of intra-aneurysmal pressure in the canine model
Abstract
Objective: The clinical significance and treatment of retrograde collateral arterial perfusion of abdominal aortic aneurysms after endovascular repair (type II endoleak) have not been completely characterized. A canine abdominal aortic aneurysm model of type II endoleak with an implanted pressure transducer was used to evaluate the use of polyurethane foam to induce thrombosis of type II endoleaks. The effect on endoleak patency, intra-aneurysmal pressure, and thrombus histology was studied.
Methods: Prosthetic aneurysms with an intraluminal, solid-state, strain-gauge pressure transducer were created in the infrarenal aorta of 14 mongrel dogs. Aneurysm side-branch vessels were reimplanted into the prosthetic aneurysm of 10 animals by using a Carrel patch. Type II (retrograde) endoleaks were created by excluding the aneurysm from antegrade perfusion with an impermeable stent graft. Thrombosis of the type II endoleak was induced by implantation of polyurethane foam into the prosthetic aneurysm sac of four animals. Six animals with type II endoleaks were not treated. In four control animals, no collateral side branches were reimplanted, and therefore no endoleak was created. Intra-aneurysmal and systemic pressures were measured daily for 60 to 90 days after the implantation of the stent graft. Endoleak patency and flow were assessed during surgery and at the time of death by using angiographic imaging and duplex ultrasonography. Histologic analysis of the intra-aneurysmal thrombus was also performed.
Results: Intra-aneurysmal pressure values are indexed to systemic pressure and are represented as a percentage of the simultaneously obtained systemic pressure, which has a value of 1.0. All six animals with untreated type II endoleaks maintained patency of the endoleak and side-branch arteries throughout the study period. Compared with control aneurysms that had no endoleak, animals with patent type II endoleaks exhibited significantly higher intra-aneurysmal pressurization (systolic pressure: patent type II endoleak, 0.702 +/- 0.283; control, 0.172 +/- 0.091; P < .001; mean pressure: endoleak, 0.784 +/- 0.229; control, 0.137 +/- 0.102; P < .001; pulse pressure: endoleak, 0.406 +/- 0.248; control, 0.098 +/- 0.077; P < .001; P < .001 for comparison for all groups by analysis of variance). Treatment of the type II endoleak with polyurethane foam induced thrombosis of the endoleak and feeding side-branch arteries in all four animals with type II endoleaks. This resulted in intra-aneurysmal pressures statistically indistinguishable from the controls (systolic pressure, 0.183 +/- 0.08; mean pressure, 0.142 +/- 0.09; pulse pressure, 0.054 +/- 0.04; not significant). Angiography and histology documented persistent patency up to the time of death (mean, 64 days) for untreated type II endoleaks and confirmed thrombosis of polyurethane foam-treated endoleaks in all cases.
Conclusions: Untreated type II endoleaks were associated with intra-aneurysmal pressures that were 70% to 80% of systemic pressure. Treatment with polyurethane foam resulted in a reduction of intra-aneurysmal pressure to a level that was indistinguishable from control aneurysms that had no endoleak.
Clinical relevance: Endovascular repair of abdominal aortic aneurysms is dependent on the successful exclusion of the aneurysm from arterial circulation. Type II endoleaks originate from retrograde flow into the aneurysm sac. This study demonstrates the use of polyurethane foam to induce thrombosis in a canine model of a type II endoleak, thereby reducing intra-aneurysmal pressure to levels similar to levels in animals without endoleaks. This approach may be a strategy for future treatment of type II endoleaks.
Similar articles
-
Characterization of retrograde collateral (type II) endoleak using a new canine model.J Vasc Surg. 2004 Nov;40(5):985-94. doi: 10.1016/j.jvs.2004.07.049. J Vasc Surg. 2004. PMID: 15557915
-
A canine model to study the significance and hemodynamics of type II endoleaks.J Surg Res. 2005 Feb;123(2):275-83. doi: 10.1016/j.jss.2004.08.022. J Surg Res. 2005. PMID: 15680390
-
Evaluation of the accuracy of a wireless pressure sensor in a canine model of retrograde-collateral (type II) endoleak and correlation with histologic analysis.J Vasc Surg. 2006 Dec;44(6):1306-13. doi: 10.1016/j.jvs.2006.08.031. J Vasc Surg. 2006. PMID: 17145435
-
Flow-diverting stents for the treatment of arterial aneurysms.J Vasc Surg. 2012 Sep;56(3):839-46. doi: 10.1016/j.jvs.2012.04.020. Epub 2012 Jul 26. J Vasc Surg. 2012. PMID: 22840737 Review.
-
Intervention after endovascular aneurysm repair: Endosalvage techniques including perigraft arterial sac embolization and endograft relining.Semin Vasc Surg. 2016 Mar;29(1-2):41-49. doi: 10.1053/j.semvascsurg.2016.06.002. Epub 2016 Jun 11. Semin Vasc Surg. 2016. PMID: 27823589 Review.
Cited by
-
A Porous Media Model for Blood Flow within Reticulated Foam.Chem Eng Sci. 2013 Aug 9;99:59-66. doi: 10.1016/j.ces.2013.05.025. Chem Eng Sci. 2013. PMID: 24031095 Free PMC article.
-
Thoracic aortic aneurysm. An experimental model in pigs.Acta Cir Bras. 2021 Jun 25;36(6):e360602. doi: 10.1590/ACB360602. eCollection 2021. Acta Cir Bras. 2021. PMID: 34190838 Free PMC article.
-
Reticulation of low density shape memory polymer foam with an in vivo demonstration of vascular occlusion.J Mech Behav Biomed Mater. 2014 Dec;40:102-114. doi: 10.1016/j.jmbbm.2014.07.037. Epub 2014 Aug 11. J Mech Behav Biomed Mater. 2014. PMID: 25222869 Free PMC article.
-
Injectable Shear-Thinning Hydrogels with Sclerosing and Matrix Metalloproteinase Modulatory Properties for the Treatment of Vascular Malformations.Adv Funct Mater. 2023 Dec 15;33(51):2305880. doi: 10.1002/adfm.202305880. Epub 2023 Sep 8. Adv Funct Mater. 2023. PMID: 38558868 Free PMC article.
-
Design and biocompatibility of endovascular aneurysm filling devices.J Biomed Mater Res A. 2015 Apr;103(4):1577-94. doi: 10.1002/jbm.a.35271. Epub 2014 Aug 4. J Biomed Mater Res A. 2015. PMID: 25044644 Free PMC article. Review.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources