Use of monoatomic and polyatomic projectiles for the characterisation of polylactic acid by static secondary ion mass spectrometry
- PMID: 16106345
- DOI: 10.1002/rcm.2089
Use of monoatomic and polyatomic projectiles for the characterisation of polylactic acid by static secondary ion mass spectrometry
Abstract
The application of polyatomic primary ions is a strongly developing branch of static secondary ion mass spectrometry (S-SIMS), since these projectiles allow a significant increase in the secondary ion yields to be achieved. However, the different limitations and possibilities of certain polyatomic primary ions for use on specific functional classes of samples are still not completely known. This paper compares the use of monoatomic and polyatomic primary ions in S-SIMS for thin layers of polylactic acid (PLA), obtained by spin-coating solutions on silicon wafers. Bombardment with Ga+, Xe+ and SF5+ primary ions allowed the contribution of the projectile mass and number of atoms in the gain in ion yield and molecular specificity (relative importance of high m/z and low m/z signals) to be assessed. Samples obtained by spin-coating solutions with increasing concentration showed that optimal layer thickness depended on the primary ion used. In comparison with the use of Ga+ projectiles, the yield of structural ions increased by a factor of about 1.5 to 2 and by about 7 to 12 when Xe+ and SF5+ primary ion bombardment were applied, respectively. A detailed fragmentation pattern was elaborated to interpret ion signal intensity changes for different projectiles in terms of energy deposition and collective processes in the subsurface, and the internal energy of radical and even-electron precursor ions.
Copyright (c) 2005 John Wiley & Sons, Ltd.
Similar articles
-
Comparison of primary monoatomic with primary polyatomic ions for the characterisation of polyesters with static secondary ion mass spectrometry.Rapid Commun Mass Spectrom. 2005;19(4):552-60. doi: 10.1002/rcm.1824. Rapid Commun Mass Spectrom. 2005. PMID: 15666315
-
Ion yield improvement for static secondary ion mass spectrometry by use of polyatomic primary ions.Rapid Commun Mass Spectrom. 2008 May;22(10):1481-96. doi: 10.1002/rcm.3533. Rapid Commun Mass Spectrom. 2008. PMID: 18401858
-
Effects of metal nanoparticles on the secondary ion yields of a model alkane molecule upon atomic and polyatomic projectiles in secondary ion mass spectrometry.Anal Chem. 2008 Aug 15;80(16):6235-44. doi: 10.1021/ac800568y. Epub 2008 Jul 17. Anal Chem. 2008. PMID: 18630928
-
Developments in molecular SIMS depth profiling and 3D imaging of biological systems using polyatomic primary ions.Mass Spectrom Rev. 2011 Jan-Feb;30(1):142-74. doi: 10.1002/mas.20275. Mass Spectrom Rev. 2011. PMID: 20077559 Review.
-
Organic surfaces excited by low-energy ions: atomic collisions, molecular desorption and buckminsterfullerenes.Phys Chem Chem Phys. 2005 Oct 7;7(19):3395-406. doi: 10.1039/b509238h. Epub 2005 Aug 24. Phys Chem Chem Phys. 2005. PMID: 16273138 Review.
Cited by
-
A Simple Method for Quantification of Polyhydroxybutyrate and Polylactic Acid Micro-Bioplastics in Soils by Evolved Gas Analysis.Molecules. 2022 Mar 15;27(6):1898. doi: 10.3390/molecules27061898. Molecules. 2022. PMID: 35335267 Free PMC article.
LinkOut - more resources
Full Text Sources