Criteria for set point estimation in the volume clamp method of blood pressure measurement
- PMID: 1610779
Criteria for set point estimation in the volume clamp method of blood pressure measurement
Abstract
When blood pressure is measured in the finger using the volume clamp method the value at which the vascular volume is clamped is of crucial importance. Since the discovery of the method, several criteria of finding a correct set point have been elaborated: 1. The volume oscillations reach their maximum amplitude at cuff pressure equalling mean blood pressure. 2. The form of the diastolic portion of volume pulsations changes if the cuff pressure moves around the mean blood pressure. 3. The set point can be positioned at one third of the arterial volume. 4. The dynamic vascular compliance (DVC) may be continuously measured as the instantaneous amplitude of vascular volume oscillations is elicited by a relatively small and rapid vibration of the cuff pressure. The shape of the DVC pulse characteristically depends on the transmural pressure (TP): at negative TP (cuff pressure exceeding the blood pressure) it shows a distinct positive systolic peak, at positive TP the polarity of the DVC pulse is reversed. In contrast to the first three ways to find the set point, the last one may operate even in closed-loop performance, i.e. during the blood pressure measurement.
Similar articles
-
Vibration plethysmography: a method for studying the visco-elastic properties of finger arteries.Med Biol Eng Comput. 1997 Nov;35(6):633-7. doi: 10.1007/BF02510971. Med Biol Eng Comput. 1997. PMID: 9538539
-
A mathematical study of some biomechanical factors affecting the oscillometric blood pressure measurement.IEEE Trans Biomed Eng. 1996 Aug;43(8):761-78. doi: 10.1109/10.508540. IEEE Trans Biomed Eng. 1996. PMID: 9216149
-
The meaning of the point of maximum oscillations in cuff pressure in the indirect measurement of blood pressure--part ii.J Biomech Eng. 1980 Feb;102(1):28-33. doi: 10.1115/1.3138195. J Biomech Eng. 1980. PMID: 7382450
-
[Noninvasive, continuous measurement of finger artery pressure with the servo-plethysmo-manometer Finapres].Herz. 1989 Aug;14(4):251-9. Herz. 1989. PMID: 2676814 Review. German.
-
Arterial blood pressure measurement and pulse wave analysis--their role in enhancing cardiovascular assessment.Physiol Meas. 2010 Jan;31(1):R1-47. doi: 10.1088/0967-3334/31/1/R01. Epub 2009 Nov 26. Physiol Meas. 2010. PMID: 19940350 Review.
Cited by
-
Passive bilateral leg cycling with concomitant regional circulatory occlusion for testing mechanoreflex-metaboreflex interactions in humans.Clin Auton Res. 2020 Dec;30(6):549-556. doi: 10.1007/s10286-020-00717-x. Epub 2020 Aug 8. Clin Auton Res. 2020. PMID: 32770375 Free PMC article.
-
Does blood pressure variability contribute to risk stratification? Methodological issues and a review of outcome studies based on home blood pressure.Hypertens Res. 2015 Feb;38(2):97-101. doi: 10.1038/hr.2014.153. Epub 2014 Oct 16. Hypertens Res. 2015. PMID: 25319600 Review.
-
Non-Invasive Hemodynamic Monitoring System Integrating Spectrometry, Photoplethysmography, and Arterial Pressure Measurement Capabilities.Adv Sci (Weinh). 2024 Jun;11(24):e2310022. doi: 10.1002/advs.202310022. Epub 2024 Apr 22. Adv Sci (Weinh). 2024. PMID: 38647403 Free PMC article.
-
Mobile Personal Health Care System for Noninvasive, Pervasive, and Continuous Blood Pressure Monitoring: Development and Usability Study.JMIR Mhealth Uhealth. 2020 Jul 20;8(7):e18012. doi: 10.2196/18012. JMIR Mhealth Uhealth. 2020. PMID: 32459642 Free PMC article.
-
Comparative Evaluation of Crystalloid Resuscitation Rate in a Human Model of Compensated Haemorrhagic Shock.Shock. 2016 Aug;46(2):149-57. doi: 10.1097/SHK.0000000000000610. Shock. 2016. PMID: 26974423 Free PMC article. Clinical Trial.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical