Successful bridge to heart transplantation with a new left ventricular assist device
- PMID: 1610860
Successful bridge to heart transplantation with a new left ventricular assist device
Abstract
During the last 5 years, a new pneumatically driven left ventricular assist device has been implanted in 18 heart transplantation candidates who required advanced mechanical circulatory support. The mean duration of support was 80 +/- 74 days, and the cumulative support time was 1400 days. Fifteen patients were successfully supported until the time of heart transplantation. As a result of early experience, in which three of four patients died after heart transplantation because their end-organ function failed to recover, subsequent efforts were made to institute support early, before irreversible organ damage occurred. Eleven of the 12 patients in the later experience are currently alive and well at a mean follow-up of 12.6 +/- 7.5 months. No thromboembolic episodes occurred, and minimal anticoagulation was required. Furthermore, patients were able to participate in rehabilitative exercise programs, thus optimizing their transplantation status. Finally, the findings in these patients have shown the feasibility of providing long-term, or even permanent, cardiac assistance.
Similar articles
-
Implantable left ventricular assist device. Approaching an alternative for end-stage heart failure. Implantable LVAD Study Group.Circulation. 1994 Nov;90(5 Pt 2):II83-6. Circulation. 1994. PMID: 7955290 Clinical Trial.
-
Seven years' experience with the Pierce-Donachy ventricular assist device.J Thorac Cardiovasc Surg. 1988 Dec;96(6):901-11. J Thorac Cardiovasc Surg. 1988. PMID: 3057290
-
Clinical experience with the Novacor ventricular assist system. Bridge to transplantation and the transition to permanent application.J Thorac Cardiovasc Surg. 1991 Oct;102(4):578-86; discussion 586-7. J Thorac Cardiovasc Surg. 1991. PMID: 1921434 Clinical Trial.
-
[Mechanical circulatory support. 2: Ventricular assist systems].Zentralbl Chir. 1995;120(3):166-73. Zentralbl Chir. 1995. PMID: 7754717 Review. German.
-
Left ventricular assist device as a bridge to partial left ventriculectomy.Eur J Cardiothorac Surg. 1999 Jan;15 Suppl 1:S20-5; discussion S39-43. Eur J Cardiothorac Surg. 1999. PMID: 10077391 Review.
Cited by
-
Current methods for circulatory support.Tex Heart Inst J. 1994;21(4):288-95. Tex Heart Inst J. 1994. PMID: 7888804 Free PMC article. Review.
-
Advanced heart failure with reduced ejection fraction.Proc (Bayl Univ Med Cent). 2020 Jun 2;33(3):350-356. doi: 10.1080/08998280.2020.1765663. eCollection 2020 Jul. Proc (Bayl Univ Med Cent). 2020. PMID: 32675952 Free PMC article.
-
Current status of cardiac transplantation and left ventricular assist devices.Tex Heart Inst J. 2010;37(3):319-21. Tex Heart Inst J. 2010. PMID: 20548811 Free PMC article. No abstract available.
-
Mechanical circulatory support: registering a therapy in evolution.Circ Heart Fail. 2008 Sep;1(3):200-5. doi: 10.1161/CIRCHEARTFAILURE.108.782599. Circ Heart Fail. 2008. PMID: 19808290 Free PMC article. Review. No abstract available.
-
Immunochemical identification of human endothelial cells on the lining of a ventricular assist device.Tex Heart Inst J. 1993;20(2):78-82. Tex Heart Inst J. 1993. PMID: 8392881 Free PMC article.
MeSH terms
LinkOut - more resources
Medical
Research Materials