Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2005 Sep;81(3):340-9.
doi: 10.1016/j.exer.2005.02.006.

Pattern electroretinography in a rat model of ocular hypertension: functional evidence for early detection of inner retinal damage

Affiliations

Pattern electroretinography in a rat model of ocular hypertension: functional evidence for early detection of inner retinal damage

Gil Ben-Shlomo et al. Exp Eye Res. 2005 Sep.

Abstract

With the increasing use of the rat as an animal model for glaucoma and for the evaluation of neuroprotective treatments, there is a need for a sensitive test of retinal ganglion cell (RGC) function in this species. The aims of this study were to detect functional abnormalities of the inner retina in a rat model of high intraocular pressure (IOP) using the pattern electroretinogram (PERG), and to correlate them with morphometric analysis of RGC survival and the functional integrity of the inner retina. Unilateral ocular hypertension was induced in 17 Lewis rats through laser photocoagulation. Pattern ERGs were recorded prior to lasering and 3 weeks later, using a series of shifting patterns of decreasing spatial frequency projected directly onto the animals' fundus. IOP was measured at the same intervals, and the number of surviving RGCs estimated. Low amplitude PERG signals could be recorded in response to a narrow grating of 0.368 cycles per degree (cpd), and increased with stimulus size. Lasering caused mean (+/-s.d.) IOP to increase significantly from 18.3+/-4.5 (baseline) to 29.8+/-8.8 mmHg within 3 weeks (p<0.0001). At this time, PERG amplitudes were significantly reduced (p<0.05), declining an average of 45% compared to the normotensive, control eyes. No outer retinal damage was observed, but the mean number of RGCs decreased significantly (p<0.001), from 2 525.0+/-372.4 to 1 542.8+/-333.8 cells per mm2. This decrease in RGC number was significantly (p=0.03) correlated the decrease in PERG amplitude. The correlation between functional integrity of the inner retina and the rat PERG was further demonstrated by intravitreal tetrodotoxin injections, which temporarily abolished the PERG but did not affect outer retinal activity, reflected in the flash ERG. The evidence for early functional deficits, combined with tonometry and documentation of correlated ganglion cells loss, confirms the sensitivity of this diagnostic tool and the validity and importance of this animal model in glaucoma research.

PubMed Disclaimer

Publication types