Comprehensive two-dimensional gas chromatography with isotope dilution time-of-flight mass spectrometry for the measurement of dioxins and polychlorinated biphenyls in foodstuffs. Comparison with other methods
- PMID: 16130655
- DOI: 10.1016/j.chroma.2005.05.090
Comprehensive two-dimensional gas chromatography with isotope dilution time-of-flight mass spectrometry for the measurement of dioxins and polychlorinated biphenyls in foodstuffs. Comparison with other methods
Abstract
A comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry (GC x GC-TOF-MS) experimental setup was tested for the measurement of seven 2,3,7,8-substituted polychlorinated dibenzo-p-dioxins (PCDDs), ten 2,3,7,8-substituted polychlorinated dibenzofurans (PCDFs), four non-ortho-polychlorinated biphenyls (PCBs), eight mono-ortho-PCBs, and six indicator PCBs (Aroclor 1260) in foodstuff samples. A 40m RTX-500 (0.18mm I.D., 0.10 microm df) was used as the first dimension (1D) and a 1.5 m BPX-50 (0.10mm I.D., 0.10 microm df) as the second dimension (2D). The GC x GC chromatographic separation was completed in 45 min. Quantification was performed using 13C-label isotope dilution (ID). Isotope ratios of the selected quantification ions were checked against theoretical values prior to peak assignment and quantification. The dynamic working range spanned three orders of magnitude. The lowest detectable amount of 2,3,7,8-TCDD was 0.2 pg. Fish, pork, and milk samples were considered. On a congener basis, the GC x GC-ID-TOF-MS method was compared to the reference GC-ID high resolution mass spectrometry (HRMS) method and to the alternative GC-ID tandem-in-time quadrupole ion storage mass spectrometry (QIST-MS/MS). PCB levels ranged from low picogram (pg) to low nanogram (ng) per gram of sample and data compared very well between the different methods. For all matrices, PCDD/Fs were at a low pg level (0.05-3 pg) on a fresh weight basis. Although congener profiles were accurately described, RSDs of GC x GC-ID-TOF-MS and GC-QIST-MS/MS were much higher than for GC-ID-HRMS, especially for low level pork and milk. On a toxic equivalent (TEQ) basis, all methods, including the dioxin-responsive chemically activated luciferase gene expression (DR-CALUX) assay, produced similar responses. A cost comparison is also presented.
Similar articles
-
Triple quadrupole tandem mass spectrometry: A real alternative to high resolution magnetic sector instrument for the analysis of polychlorinated dibenzo-p-dioxins, furans and dioxin-like polychlorinated biphenyls.Anal Chim Acta. 2015 Aug 19;889:156-65. doi: 10.1016/j.aca.2015.07.039. Epub 2015 Aug 10. Anal Chim Acta. 2015. PMID: 26343438
-
Ion-trap tandem mass spectrometry for the analysis of polychlorinated dibenzo-p-dioxins, dibenzofurans, and dioxin-like polychlorinated biphenyls in food.J Agric Food Chem. 2007 Dec 26;55(26):10531-9. doi: 10.1021/jf0719858. Epub 2007 Dec 4. J Agric Food Chem. 2007. PMID: 18052095
-
The use of the DR CALUX bioassay and indicator polychlorinated biphenyls for screening of elevated levels of dioxins and dioxin-like polychlorinated biphenyls in eel.Mol Nutr Food Res. 2006 Oct;50(10):945-57. doi: 10.1002/mnfr.200600061. Mol Nutr Food Res. 2006. PMID: 17009214
-
The need and potential of biosensors to detect dioxins and dioxin-like polychlorinated biphenyls along the milk, eggs and meat food chain.Sensors (Basel). 2011;11(12):11692-716. doi: 10.3390/s111211692. Epub 2011 Dec 15. Sensors (Basel). 2011. PMID: 22247688 Free PMC article. Review.
-
THE DEVELOPMENT OF A HIGH-RESOLUTION MASS SPECTROMETRY METHOD FOR ULTRA-TRACE ANALYSIS OF CHLORINATED DIOXINS IN ENVIRONMENTAL AND BIOLOGICAL SAMPLES INCLUDING VIET NAM ERA VETERANS.Mass Spectrom Rev. 2021 May;40(3):236-254. doi: 10.1002/mas.21639. Epub 2020 Jun 12. Mass Spectrom Rev. 2021. PMID: 32530096 Review.
Cited by
-
Serum dioxin-like activity is associated with reproductive parameters in young men from the general Flemish population.Environ Health Perspect. 2006 Nov;114(11):1670-6. doi: 10.1289/ehp.9224. Environ Health Perspect. 2006. PMID: 17107851 Free PMC article.
-
QUICK: Quality and Usability Investigation and Control Kit for Mass Spectrometric Data from Detection of Persistent Organic Pollutants.Int J Environ Res Public Health. 2019 Oct 30;16(21):4203. doi: 10.3390/ijerph16214203. Int J Environ Res Public Health. 2019. PMID: 31671576 Free PMC article.
-
Resolution, quantification, and reliable determination of enantiomeric excess of proteinogenic and non-proteinogenic amino acids by comprehensive two-dimensional gas chromatography.J Sep Sci. 2022 Dec;45(24):4416-4426. doi: 10.1002/jssc.202200606. Epub 2022 Oct 17. J Sep Sci. 2022. PMID: 36214089 Free PMC article.
-
Persistent Organic Pollutants in Food: Contamination Sources, Health Effects and Detection Methods.Int J Environ Res Public Health. 2019 Nov 8;16(22):4361. doi: 10.3390/ijerph16224361. Int J Environ Res Public Health. 2019. PMID: 31717330 Free PMC article. Review.
-
Enhanced characterization of the smell of death by comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry (GCxGC-TOFMS).PLoS One. 2012;7(6):e39005. doi: 10.1371/journal.pone.0039005. Epub 2012 Jun 18. PLoS One. 2012. PMID: 22723918 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous