Randomized Controlled Trial
. 2006 Feb;16(2):473-8.
doi: 10.1007/s00330-005-2865-z. Epub 2005 Aug 16.

Prospective evaluation of two different injection techniques for MR arthrography of the hip

Affiliations
Randomized Controlled Trial

Prospective evaluation of two different injection techniques for MR arthrography of the hip

Sylvain R Duc et al. Eur Radiol. 2006 Feb.

Abstract

The aim of the study was to evaluate prospectively the technical feasibility and discomfort of two different injection techniques for MR arthrography of the hip. Sixty-one consecutive patients undergoing MR arthrography of the hip (68 hips) were randomly injected either at the femoral head (36 hips) or the femoral neck (32 hips). The patients rated discomfort during and 0-72 h after arthrography using a visual analogue scale (VAS, 0="did not feel anything", 100="unbearable"). The volume injected, the distance between the needle tract and the neurovascular bundle, the duration of the procedure and the extra-articular contrast leakage were measured. No significant differences were found for the volume injected, the distance between the needle tract and the neurovascular bundle, or the procedure duration. Volume of extra-articular contrast leakage was statistically significantly different (head 1+/-2 cm(3), neck 3+/-5 cm(3), P=0.024). The VAS score for needle advancement was significantly different (head 25+/-20, neck 19+/-23, P=0.031). No significant differences were found for the VAS score regarding delayed discomfort. Before the examination the arthrography-related discomfort was overestimated by 74% (50/68), correctly anticipated by 22% (15/68) and underestimated by 4% (3/68) of the patients. MR-related discomfort was overestimated by 32% (22/68), correctly anticipated by 57% (39/68) and underestimated by 10% (7/68) of the patients. Both hip puncture techniques were well tolerated. The neck injection technique produced less discomfort and was associated with greater extra-articular contrast leakage.

PubMed Disclaimer

References

    1. Clin Orthop Relat Res. 1973 Jun;(93):260-4 - PubMed
    1. Radiology. 1997 Aug;204(2):580-2 - PubMed
    1. Crit Rev Diagn Imaging. 1980;13(2):111-71 - PubMed
    1. Am J Roentgenol Radium Ther Nucl Med. 1952 Jul;68(1):107-11 - PubMed
    1. J Bone Joint Surg Am. 1971 Jun;53(4):701-9 - PubMed

Publication types

MeSH terms

LinkOut - more resources