Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Case Reports
. 2005 Sep;94(9):588-91.
doi: 10.1007/s00392-005-0272-8.

Transvenous ICD implantation after artificial tricuspid valve replacement. A new approach placing a transvenous ICD lead in the mid cardiac vein of the coronary sinus

Affiliations
Case Reports

Transvenous ICD implantation after artificial tricuspid valve replacement. A new approach placing a transvenous ICD lead in the mid cardiac vein of the coronary sinus

R Gradaus et al. Z Kardiol. 2005 Sep.

Abstract

Implantation of a transvenous device in patients with a tricuspid valve replacement or a complex congenital heart disease with no access to the right ventricle represents problems. The lack of access to the right ventricle might preclude transvenous placement of a defibrillation lead at ICD implantation. A young patient (21 years) with a history of severe chest trauma with rupture of the tricuspid valve as well as the right coronary artery and consecutive inferior myocardial infarction was initially treated with tricuspid valve replacement (St Jude Medical artificial prosthesis, 33 mm) and a bypass graft to the right coronary artery. Four years later, the patient was admitted with a hemodynamically not tolerated ventricular tachycardia (VT: CL 250 ms, LBBB, left axis). The VT could be reproduced during electrophysiological testing. An ICD was implanted subpectorally in combination with a transvenous active fixation ICD lead. The transvenous ICD lead was placed via a guiding catheter into a coronary sinus branch (middle cardiac vein). Acceptable pacing and sensing values could be obtained. The defibrillation threshold was 25 J. In conclusion transvenous ICD lead implantation into a side branch of the coronary sinus in combination with a pectorally implanted "active can" ICD device seems to be an alternative approach. This approach may avoid implantation of additional subcutaneous defibrillation leads or even thoracotomy for ICD implantation.

PubMed Disclaimer

References

    1. Circulation. 2000 Mar 21;101(11):1297-302 - PubMed
    1. N Engl J Med. 1997 Nov 27;337(22):1576-83 - PubMed
    1. Circulation. 2000 Aug 15;102(7):748-54 - PubMed
    1. Pacing Clin Electrophysiol. 2001 Aug;24(8 Pt 1):1291-2 - PubMed
    1. Pacing Clin Electrophysiol. 2000 Nov;23(11 Pt 1):1698-9 - PubMed

Publication types

MeSH terms

LinkOut - more resources