Clinical Trial
. 2005 Sep;159(9):868-75.
doi: 10.1001/archpedi.159.9.868.

Pressure-regulated volume control ventilation vs synchronized intermittent mandatory ventilation for very low-birth-weight infants: a randomized controlled trial

Affiliations
Clinical Trial

Pressure-regulated volume control ventilation vs synchronized intermittent mandatory ventilation for very low-birth-weight infants: a randomized controlled trial

Carl T D'Angio et al. Arch Pediatr Adolesc Med. 2005 Sep.

Abstract

Objective: To test the hypothesis that pressure-regulated volume control (PRVC), an assist/control mode of ventilation, would increase the proportion of very low-birth-weight infants who were alive and extubated at 14 days of age as compared with synchronized intermittent mandatory ventilation (SIMV).

Study design: Ventilated infants with birth weight of 500 to 1249 g were randomized at less than 6 hours of age either to pressure-limited SIMV or to PRVC on the Servo 300 ventilator (Siemens Electromedical Group, Danvers, Mass). Infants received their assigned mode of ventilation until extubation, death, or meeting predetermined failure criteria.

Results: Mean +/- SD birth weights were similar in the SIMV (888 +/- 199 g, n = 108) and PRVC (884 +/- 203 g, n = 104) groups. No differences were detected between SIMV and PRVC groups in the proportion of infants alive and extubated at 14 days (41% vs 37%, respectively), length of mechanical ventilation in survivors (median, 24 days vs 33 days, respectively), or the proportion of infants alive without a supplemental oxygen requirement at 36 weeks' postmenstrual age (57% vs 63%, respectively). More infants receiving SIMV (33%) failed their assigned ventilator mode than did infants receiving PRVC (20%). Including failure as an adverse outcome did not alter the overall outcome (39% of infants in the SIMV group vs 35% of infants in the PRVC group were alive, extubated, and had not failed at 14 days).

Conclusion: In mechanically ventilated infants with birth weights of 500 to 1249 g, using PRVC ventilation from birth did not alter time to extubation.

PubMed Disclaimer

Publication types

MeSH terms