. 2005 Sep;33(9):2022-7.
doi: 10.1097/01.ccm.0000178190.89663.e5.

The effect of process control on the incidence of central venous catheter-associated bloodstream infections and mortality in intensive care units in Mexico

Affiliations

The effect of process control on the incidence of central venous catheter-associated bloodstream infections and mortality in intensive care units in Mexico

Francisco Higuera et al. Crit Care Med. 2005 Sep.

Abstract

Purpose: To ascertain the effect of an infection control program including process control on intensive care unit (ICU) rates of intravascular device (IVD)-associated bloodstream infection (BSI).

Setting: Two level III adult ICUs in one public university hospital in Mexico: one medical surgical ICU and one neurosurgical ICU. POPULATION STUDY: All adult patients admitted to study units who had a central venous catheter (CVC) in place for at least 24 hrs.

Methods: A prospective before/after trial in which rates of IVD-associated BSI are determined during a period of active surveillance without process control (phase 1) were compared with rates of IVD-associated BSI after implementing an infection control program applying process control (phase 2).

Results: Six hundred five IVD-days were accumulated in phase 1, and 2824 IVD-days were accumulated during phase 2. Compliance with CVC site care and hand hygiene improved significantly from baseline during the study period: placing a gauze dressing over the catheter insertion site (99.24% vs. 86.69%, respectively; relative risk [RR] = 1.14; 95% confidence interval [CI] = 1.07-1.22; p = .0000), proper use of gauze for vascular catheter insertion site (97.87% vs. 84.21%, respectively; RR = 1.16; 95% CI = 1.09-1.24; p = .0000), documentation of the duration of the administration set of the vascular catheter (93.85% vs. 40.69%, respectively; RR = 2.34; 95% CI = 2.14-2.56; p = .0000), and hand hygiene before contact with the patient (84.9% vs. 62%, respectively; RR = 1.37; 95% CI = 1.21-1.51; p = .0000). Overall rates of IVD-associated BSI were lowered significantly from baseline rates after implementation of process control (19.5 vs. 46.3 BSIs per 1000 IVD-days, respectively; RR = 0.42; 95% CI = 0.27-0.66; p = .0001). Overall rates of crude unadjusted mortality were lowered significantly from baseline rates (48.5% vs. 32.8% per 100 discharges, respectively; RR = 0.68; 95% CI = 0.50-0.31; p = .01).

Conclusion: Implementation of an infection control program utilizing education, process control, and performance feedback was associated with significant reductions in rates of IVD-associated BSI and mortality.

PubMed Disclaimer

Comment in

Publication types

LinkOut - more resources