Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2005 Sep;79(3):199-206.
doi: 10.1079/joh2005305.

Urinary schistosomiasis on Zanzibar: application of two novel assays for the detection of excreted albumin and haemoglobin in urine

Affiliations

Urinary schistosomiasis on Zanzibar: application of two novel assays for the detection of excreted albumin and haemoglobin in urine

D Rollinson et al. J Helminthol. 2005 Sep.

Abstract

As part of a urinary schistosomiasis control programme on Zanzibar, an aged cross-sectional survey of 305 children from three schools on Unguja was conducted to investigate the relationships between levels of excreted albumin and haemoglobin in urine and Schistosoma haematobium infection status. Diagnosis was determined by standard parasitological methods, dipstick reagents for microhaematuria, visual inspection for macrohaematuria as well as collection of case-history questionnaire data for self-diagnosis. Prevalence of infection as determined by parasitology was 53.9% and approximately, one quarter of the children examined were anaemic (<11 g dl(-1)). A statistically significant negative association of blood haemoglobin levels of boys and S. haematobium infection intensity status was observed (rs=-0.23, P=0.005). Through sensitivity analysis of urine-albumin values it was determined that a concentration of above >40 mg l(-1), as measured with the HemoCue urine-albumin photometer, had sensitivity, specificity, positive and negative predictive values of 0.90, 0.83, 0.86 and 0.89 respectively against 'gold-standard' parasitology. There was a clear association of reported pain upon micturition for children with elevated urine-albumin levels, with an odds ratio of 20 to 1. Levels of excreted blood in urine were quantified with the HemoCue Plasma/Low Hb photometer. However, dipsticks remain the method of choice for urine-haemoglobin of 0.1 g l(-1) and below. Urine parameters over a 24-h period were assessed in a small sub-sample. Reductions in both albumin and haemoglobin excretion were observed in 11 children 54 days after praziquantel treatment. It was concluded that these rapid, high-through-put, portable HemoCue assays could play a role in better describing and monitoring the occurrence, severity and evolution of urinary schistosomiasis disease. The urine-albumin assay has particular promise as a biochemical marker of S. haematobium induced kidney- and upper urinary tract-morbidity.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms