The role of arbitration of discordant reports at double reading of screening mammograms
- PMID: 16156942
- DOI: 10.1258/0969141054855337
The role of arbitration of discordant reports at double reading of screening mammograms
Abstract
Objective: To asses the effectiveness of arbitration of discordant double readings in mammography screening.
Design: A retrospective study of 1217 consecutive arbitrations.
Setting: A subset of discordant double readings from the Florence screening programme underwent arbitration by a third reader.
Results: Positive arbitration of 1217 discordant double readings prompted assessment in 476 cases (39.2%), detecting 30 cancers (6.3%). Of 741 negative arbitrations (60.8%), 311 have been followed up thus far, and two cancers (0.64%) occurred in the site previously suspected at one of the two independent readings. Arbitration had a sensitivity of 86.3% and a negative predictive value of 99.3%. Arbitration reduced the overall referral rates from 3.82% to 2.59% (relative decrease 32.1%). Due to false-negative arbitration, cancers detected per 1000 women screened would decrease from 4.58 to 4.50 (relative decrease 1.7%). For every cancer missed due to false-negative arbitration, 151 unnecessary recalls and 21,248 euro would have been saved, whereas the saved cost per screened woman due to arbitration was 1.72 euro.
Discussion: Arbitration of discordant double reading would substantially reduce referral rates with a limited reduction in cancer detection rate, and may be recommended as a routine procedure. Greater benefit from arbitration might be expected in the presence of high referral rates at independent double reading, a common scenario in a newly implemented service screening.
Similar articles
-
Second reading of screening mammograms increases cancer detection and recall rates. Results in the Florence screening programme.J Med Screen. 2005;12(2):103-6. doi: 10.1258/0969141053908285. J Med Screen. 2005. PMID: 15949122
-
On the role of arbitration of discordant double readings of screening mammography: experience from two Italian programmes.Radiol Med. 2011 Feb;116(1):84-91. doi: 10.1007/s11547-010-0606-0. Epub 2010 Oct 27. Radiol Med. 2011. PMID: 20981500 English, Italian.
-
Does computer-aided detection have a role in the arbitration of discordant double-reading opinions in a breast-screening programme?Clin Radiol. 2009 Jan;64(1):46-51. doi: 10.1016/j.crad.2008.07.008. Epub 2008 Sep 4. Clin Radiol. 2009. PMID: 19070697
-
Controversies in mammography.N J Med. 2005 Jan-Feb;102(1-2):45-9. N J Med. 2005. PMID: 15790065 Review.
-
Computer aids and human second reading as interventions in screening mammography: two systematic reviews to compare effects on cancer detection and recall rate.Eur J Cancer. 2008 Apr;44(6):798-807. doi: 10.1016/j.ejca.2008.02.016. Epub 2008 Mar 18. Eur J Cancer. 2008. PMID: 18353630 Review.
Cited by
-
Performance of double reading mammography in an Iranian population and its effect on patient outcome.Iran J Radiol. 2013 Jun;10(2):51-5. doi: 10.5812/iranjradiol.11729. Epub 2013 May 20. Iran J Radiol. 2013. PMID: 24046778 Free PMC article.
-
Prospective trial comparing full-field digital mammography (FFDM) versus combined FFDM and tomosynthesis in a population-based screening programme using independent double reading with arbitration.Eur Radiol. 2013 Aug;23(8):2061-71. doi: 10.1007/s00330-013-2820-3. Epub 2013 Apr 4. Eur Radiol. 2013. PMID: 23553585 Free PMC article.
-
Effect of protocol-related variables and women's characteristics on the cumulative false-positive risk in breast cancer screening.Ann Oncol. 2012 Jan;23(1):104-111. doi: 10.1093/annonc/mdr032. Epub 2011 Mar 23. Ann Oncol. 2012. PMID: 21430183 Free PMC article.
-
Is the false-positive rate in mammography in North America too high?Br J Radiol. 2016 Sep;89(1065):20160045. doi: 10.1259/bjr.20160045. Epub 2016 Jun 8. Br J Radiol. 2016. PMID: 27187600 Free PMC article. Review.
-
Service and clinical impacts of reader bias in breast cancer screening: a retrospective study.Br J Radiol. 2024 Jan 23;97(1153):120-125. doi: 10.1093/bjr/tqad024. Br J Radiol. 2024. PMID: 38263824 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical