Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2005 Sep;383(2):327-40.
doi: 10.1007/s00216-005-0016-7. Epub 2005 Oct 12.

Alkane effect in the Arizona liquid systems used in countercurrent chromatography

Affiliations

Alkane effect in the Arizona liquid systems used in countercurrent chromatography

A Berthod et al. Anal Bioanal Chem. 2005 Sep.

Abstract

Countercurrent chromatography (CCC) is a separation technique that uses a biphasic liquid system; one liquid phase is the mobile phase, the other liquid phase is the stationary phase. Selection of the appropriate liquid system can be a problem in CCC, since it is necessary to select both the "column" and the mobile phase at the same time as the first is completely dependent on the second. A range of systems with various proportions of solvents were developed to ease this choice; 23 variations of the heptane/ethyl acetate/methanol/water biphasic liquid system were labeled A to Z. This range proved to be extremely useful and became the popular Arizona (AZ) liquid system. However, authors often replace the heptane with hexane. In this work, the chemical compositions of the upper phases and the lower phases of 55 Arizona systems made with various alkanes (pentane, hexane, heptane, isooctane and cyclohexane) were determined by gas chromatography and Karl Fischer titration. The test mixture separated consisted of five steroid compounds. The lower phases were found to have similar compositions when different alkanes were used, but the upper phases were found to change. Exchanging heptane for hexane or isooctane produced minimal changes in the CCC chromatogram, while changing the proportions of the solvents resulted in an exponential change in the retention volumes. The high density of cyclohexane made liquid stationary phase retention difficult. All Arizona systems equilibrated within 30 min, but were not stable: water slowly hydrolyzed the ethyl acetate (as shown by a continuous decrease in the pH of the lower aqueous phase), especially in the water-rich systems (early alphabet letters).

PubMed Disclaimer

Publication types

LinkOut - more resources