Acute genitourinary toxicity after high dose rate (HDR) brachytherapy combined with hypofractionated external-beam radiation therapy for localized prostate cancer: Second analysis to determine the correlation between the urethral dose in HDR brachytherapy and the severity of acute genitourinary toxicity
- PMID: 16168839
- DOI: 10.1016/j.ijrobp.2005.02.015
Acute genitourinary toxicity after high dose rate (HDR) brachytherapy combined with hypofractionated external-beam radiation therapy for localized prostate cancer: Second analysis to determine the correlation between the urethral dose in HDR brachytherapy and the severity of acute genitourinary toxicity
Abstract
Purpose: We have been treating localized prostate cancer with high-dose-rate (HDR) brachytherapy combined with hypofractionated external beam radiation therapy (EBRT) at our institution. We recently reported the existence of a correlation between the severity of acute genitourinary (GU) toxicity and the urethral radiation dose in HDR brachytherapy by using different fractionation schema. The purpose of this study was to evaluate the role of the urethral dose in the development of acute GU toxicity more closely than in previous studies. For this purpose, we conducted an analysis of patients who had undergone HDR brachytherapy with a fixed fractionation schema combined with hypofractionated EBRT.
Methods and materials: Among the patients with localized prostate cancer who were treated by 192-iridium HDR brachytherapy combined with hypofractionated EBRT at Gunma University Hospital between August 2000 and November 2004, we analyzed 67 patients who were treated by HDR brachytherapy with the fractionation schema of 9 Gy x two times combined with hypofractionated EBRT. Hypofractionated EBRT was administered at a fraction dose of 3 Gy three times weekly, and a total dose of 51 Gy was delivered to the prostate gland and seminal vesicles using the four-field technique. No elective pelvic irradiation was performed. After the completion of EBRT, all the patients additionally received transrectal ultrasonography-guided HDR brachytherapy. The planning target volume was defined as the prostate gland with a 5-mm margin all around, and the planning was conducted based on computed tomography images. The tumor stage was T1c in 13 patients, T2 in 31 patients, and T3 in 23 patients. The Gleason score was 2-6 in 12 patients, 7 in 34 patients, and 8-10 in 21 patients. Androgen ablation was performed in all the patients. The median follow-up duration was 11 months (range 3-24 months). The toxicities were graded based on the Radiation Therapy Oncology Group and the European Organization for Research and Treatment of Cancer toxicity criteria.
Results: The main symptoms of acute GU toxicity were dysuria and increase in the urinary frequency or nocturia. The grade distribution of acute GU toxicity in the patients was as follows: Grade 0-1, 42 patients (63%); Grade 2-3, 25 patients (37%). The urethral dose in HDR brachytherapy was determined using the following dose-volume histogram (DVH) parameters: V30 (percentage of the urethral volume receiving 30% of the prescribed radiation dose), V80, V90, V100, V110, V120, V130, and V150. In addition, the D5 (dose covering 5% of the urethral volume), D10, D20, and D50 of the urethra were also estimated. The V30-V150 values in the patients with Grade 2-3 acute GU toxicity were significantly higher than those in patients with Grade 0-1 toxicity. The D10 and D20, but not D5 and D50, values were also significantly higher in the patients with Grade 2-3 acute GU toxicity than in those with Grade 0-1 toxicity. Regarding the influence of the number of needles implanted, there was no correlation between the number of needles implanted and the severity of acute GU toxicity or the V30-V150 values and D5-D50 values.
Conclusions: It was concluded that HDR brachytherapy combined with hypofractionated EBRT is feasible for localized prostate cancer, when considered from the viewpoint of acute toxicity. However, because the urethral dose was closely associated with the grade of severity of the acute GU toxicity, the urethral dose in HDR brachytherapy must be kept low to reduce the severity of acute GU toxicity.
Similar articles
-
Acute genitourinary toxicity after high-dose-rate (HDR) brachytherapy combined with hypofractionated external-beam radiation therapy for localized prostate cancer: correlation between the urethral dose in HDR brachytherapy and the severity of acute genitourinary toxicity.Int J Radiat Oncol Biol Phys. 2005 Oct 1;63(2):463-71. doi: 10.1016/j.ijrobp.2004.11.041. Int J Radiat Oncol Biol Phys. 2005. PMID: 16168838
-
Genitourinary toxicity after high-dose-rate (HDR) brachytherapy combined with Hypofractionated External beam radiotherapy for localized prostate cancer: an analysis to determine the correlation between dose-volume histogram parameters in HDR brachytherapy and severity of toxicity.Int J Radiat Oncol Biol Phys. 2009 Sep 1;75(1):23-8. doi: 10.1016/j.ijrobp.2008.11.006. Epub 2009 Feb 23. Int J Radiat Oncol Biol Phys. 2009. PMID: 19243900
-
Rectal bleeding after high-dose-rate brachytherapy combined with hypofractionated external-beam radiotherapy for localized prostate cancer: impact of rectal dose in high-dose-rate brachytherapy on occurrence of grade 2 or worse rectal bleeding.Int J Radiat Oncol Biol Phys. 2006 Jun 1;65(2):364-70. doi: 10.1016/j.ijrobp.2005.12.017. Int J Radiat Oncol Biol Phys. 2006. PMID: 16690428
-
Dose-volume analysis of predictors for chronic rectal toxicity after treatment of prostate cancer with adaptive image-guided radiotherapy.Int J Radiat Oncol Biol Phys. 2005 Aug 1;62(5):1297-308. doi: 10.1016/j.ijrobp.2004.12.052. Int J Radiat Oncol Biol Phys. 2005. PMID: 16029785 Review.
-
High-dose-rate intensity-modulated brachytherapy with external beam radiotherapy for prostate cancer: California endocurietherapy's 10-year results.Int J Radiat Oncol Biol Phys. 2005 Apr 1;61(5):1306-16. doi: 10.1016/j.ijrobp.2004.08.014. Int J Radiat Oncol Biol Phys. 2005. PMID: 15817332 Review.
Cited by
-
Influence of zonal dosimetry on prostate brachytherapy outcomes.J Contemp Brachytherapy. 2015 Feb;7(1):17-22. doi: 10.5114/jcb.2015.48875. Epub 2015 Feb 4. J Contemp Brachytherapy. 2015. PMID: 25829932 Free PMC article.
-
Effectiveness of Rotating Shield Brachytherapy for Prostate Cancer Dose Escalation and Urethral Sparing.Int J Radiat Oncol Biol Phys. 2018 Dec 1;102(5):1543-1550. doi: 10.1016/j.ijrobp.2018.07.2015. Epub 2018 Aug 6. Int J Radiat Oncol Biol Phys. 2018. PMID: 30092333 Free PMC article.
-
High-dose-rate interstitial brachytherapy for gynecologic malignancies--dosimetric changes during treatment period.J Radiat Res. 2013 Jul 1;54(4):663-70. doi: 10.1093/jrr/rrs130. Epub 2013 Jan 7. J Radiat Res. 2013. PMID: 23297319 Free PMC article.
-
Vital role of volume and number of needles in HDR brachytherapy (HDR-BT) of prostate cancer.J Contemp Brachytherapy. 2009 Oct;1(3):145-150. Epub 2009 Oct 8. J Contemp Brachytherapy. 2009. PMID: 27807456 Free PMC article.
-
The effect of needle number on the quality of high-dose-rate prostate brachytherapy implants.Pathol Oncol Res. 2010 Dec;16(4):593-9. doi: 10.1007/s12253-010-9252-z. Epub 2010 Mar 25. Pathol Oncol Res. 2010. PMID: 20336408
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical