Assessment of left ventricular function during upright treadmill exercise with tantalum 178 and multiwire gamma camera
- PMID: 16171716
- DOI: 10.1016/j.nuclcard.2005.05.021
Assessment of left ventricular function during upright treadmill exercise with tantalum 178 and multiwire gamma camera
Abstract
Background: Prior studies with first-pass radionuclide angiography (RNA) during treadmill exercise used a single-crystal (Anger) or multicrystal gamma camera and technetium 99m tracers. Motion correction, when done, used point sources, which limited correction to only plane movement.
Methods and results: We examined the performance of a multiwire gamma camera (MWGC), generator-produced tantalum 178, and a novel method of motion correction during treadmill exercise testing. We studied 100 patients in whom rest and stress gated tomographic myocardial perfusion images were obtained. Eight patients were excluded because of incomplete data. There were 53 men and 39 women aged 52 +/- 12 years. The resting left ventricular (LV) ejection fraction (EF) was 61% +/- 12% by gated single photon emission computed tomography. Stress myocardial perfusion was normal in 83 patients and abnormal in 9 patients. The resting RNA EF in the upright position was 57% +/- 12% (r = 0.52, P = .0001 vs gated EF). At peak exercise, the EF by MWGC was 60% +/- 26% if uncorrected and 69% +/- 13% after motion correction. Among the 80 patients with normal perfusion and normal resting EF by gated single photon emission computed tomography, a normal response to exercise was seen in 52 (63%) without motion correction and 74 (89%) with motion correction (P < .05).
Conclusion: Assessment of LV function is feasible with MWGC. The motion-corrected images significantly improved the results.
Similar articles
-
Verification of the left ventricular ejection fraction from gated myocardial perfusion studies (GSPECT).Kardiol Pol. 2005 Nov;63(5):465-75; discussion 476-7. Kardiol Pol. 2005. PMID: 16362849 Clinical Trial.
-
Site of myocardial infarction and severity of perfusion abnormalities impact on post-stress left ventricular function in patients with single-vessel disease: gated single-photon emission computed tomography methoxyisobutylisonitrile study.Nucl Med Commun. 2009 Feb;30(2):148-54. doi: 10.1097/MNM.0b013e3283176a67. Nucl Med Commun. 2009. PMID: 19077915
-
First-pass radionuclide angiography using a multiwire gamma camera and tantalum-178.J Nucl Med. 1988 Mar;29(3):293-301. J Nucl Med. 1988. PMID: 3346739
-
Perfusion and function assessment by nuclear cardiology techniques.Curr Opin Cardiol. 1997 Nov;12(6):581-6. doi: 10.1097/00001573-199711000-00013. Curr Opin Cardiol. 1997. PMID: 9429831 Review.
-
Tracking a therapeutic response: how reliable are serial measurements of LV perfusion and function?J Nucl Cardiol. 2012 Apr;19(2):360-3. doi: 10.1007/s12350-012-9518-9. J Nucl Cardiol. 2012. PMID: 22297852 Free PMC article. Review. No abstract available.
Cited by
-
The role of first-pass radionuclide angiography in the era of gated SPECT myocardial perfusion imaging.J Nucl Cardiol. 2008 Nov-Dec;15(6):838-40. doi: 10.1007/BF03007366. Epub 2008 Sep 7. J Nucl Cardiol. 2008. PMID: 18984460 No abstract available.
-
Effect of patient positioning on the evaluation of myocardial perfusion SPECT.J Nucl Cardiol. 2018 Oct;25(5):1645-1654. doi: 10.1007/s12350-017-0865-4. Epub 2017 Mar 30. J Nucl Cardiol. 2018. PMID: 28361477
References
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Medical