CyberKnife Frameless Radiosurgery for the treatment of extracranial benign tumors
- PMID: 16173828
- DOI: 10.1177/153303460500400511
CyberKnife Frameless Radiosurgery for the treatment of extracranial benign tumors
Abstract
Limited data exists for the use of radiosurgery for benign extracranial tumors. The purpose of this study was to evaluate the feasibility, toxicity, and local control of patients with benign extracranial lesions treated with the CyberKnife Frameless Radiosurgery System. From September 2001 thru January 2004, 59 benign tumors in 44 patients were treated using the CyberKnife a frameless image-guided radiosurgery system. Of these tumors, there were 21 neurofibromas, ten schwannomas, eight meningiomas, eight hemangioblastomas, seven paragangliomas, two hemangiopericytomas, one pseudotumor, one ependymoma, and one arteriovenous malformation (AVM). The anatomic locations of these tumors were spinal (25 cervical, four thoracic, 14 lumbar, and two sacral), neck (eight), orbital (three), brainstem (one), and foramen magnum (one). All patients were treated in a single fraction except three lesions were treated in a fractionated manner. The median treatment delivery time per fraction was 59 minutes (range 11-194). Twenty three lesions initially underwent surgical resection. Ten lesions received prior external beam radiation with a median dose 48 Gy (range 40-54 Gy), and one lesion received two prior CyberKnife treatments for a total dose of 32 Gy to the 80% isodose line. The median follow-up was eight months (range 1-25 months). Acute and late toxicity was graded using the National Cancer Institute Common Toxicity Criteria (CTC) scale. Symptomatic response was documented as "improved," "stable," or "progression". The median tumor dose delivered was 16.0 Gy to the 80% isodose line (range 10-31 Gy). The median tumor volume was 4.3 cc (range 0.14-98.6 cc). The median spinal cord volume receiving more than 8 Gy was 0.035 cc (range 0-2.5 cc) and the median maximum spinal cord dose 11.5 Gy (range 0-19.8 Gy). There were no patients that suffered a significant (Grade 3, 4, or 5) acute toxicity. There was no observed late toxicity. 78% of patients experienced an improvement of their pre-treatment symptoms while only one patient experienced symptom progression. Of the 26 patients who underwent follow-up imaging, the local control rate was 96%. This study suggests that CyberKnife Radiosurgery is a safe and efficacious treatment modality for benign tumors, even for those patients with recurrent previously irradiated lesions.
Similar articles
-
CyberKnife frameless stereotactic radiosurgery for spinal lesions: clinical experience in 125 cases.Neurosurgery. 2004 Jul;55(1):89-98; discussion 98-9. Neurosurgery. 2004. PMID: 15214977 Clinical Trial.
-
Radiosurgery for benign tumors of the spine using the Synergy S with cone-beam computed tomography image guidance.J Neurosurg. 2012 Dec;117 Suppl:197-202. doi: 10.3171/2012.8.GKS12981. J Neurosurg. 2012. PMID: 23205810
-
Radiosurgery for benign tumors of the spine: clinical experience and current trends.Technol Cancer Res Treat. 2012 Apr;11(2):133-9. doi: 10.7785/tcrt.2012.500242. Technol Cancer Res Treat. 2012. PMID: 22335407
-
Fractionated stereotactic radiation therapy in the management of benign cavernous sinus meningiomas : long-term experience and review of the literature.Strahlenther Onkol. 2006 Nov;182(11):635-40. doi: 10.1007/s00066-006-1548-2. Strahlenther Onkol. 2006. PMID: 17072520 Review.
-
Control of brain metastases using frameless image-guided radiosurgery.Neurosurg Focus. 2009 Dec;27(6):E6. doi: 10.3171/2009.8.FOCUS09131. Neurosurg Focus. 2009. PMID: 19951059 Review.
Cited by
-
Initial Experience With 6D Skull Tracking and Intrafractional Motion Monitoring in the United Arab Emirates' First CyberKnife® Radiosurgery Center.Cureus. 2024 Jan 11;16(1):e52143. doi: 10.7759/cureus.52143. eCollection 2024 Jan. Cureus. 2024. PMID: 38222986 Free PMC article.
-
Radiosurgery of spinal meningiomas and schwannomas.Technol Cancer Res Treat. 2012 Feb;11(1):27-34. doi: 10.7785/tcrt.2012.500231. Technol Cancer Res Treat. 2012. PMID: 22181328 Free PMC article.
-
Radiosurgery using the Cyberknife for benign spinal tumors: Korea Cancer Center Hospital experience.J Neurooncol. 2011 Jan;101(1):91-9. doi: 10.1007/s11060-010-0231-8. Epub 2010 May 28. J Neurooncol. 2011. PMID: 20508971
-
The role of stereotactic radiosurgery in the treatment of intramedullary spinal cord neoplasms: a systematic literature review.Neurosurg Rev. 2016 Apr;39(2):175-83; discussion 183. doi: 10.1007/s10143-015-0654-y. Epub 2015 Jul 30. Neurosurg Rev. 2016. PMID: 26219855
-
Cyberknife: A double edged sword?Rep Pract Oncol Radiother. 2010 Jul 6;15(4):93-7. doi: 10.1016/j.rpor.2010.05.002. Rep Pract Oncol Radiother. 2010. PMID: 24376931 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical