Electron beam CT versus 16-MDCT on the variability of repeated coronary artery calcium measurements in a variable heart rate phantom
- PMID: 16177422
- DOI: 10.2214/AJR.04.1057
Electron beam CT versus 16-MDCT on the variability of repeated coronary artery calcium measurements in a variable heart rate phantom
Abstract
Objective: High reproducibility of coronary artery calcium (CAC) scoring is a key requirement for monitoring the progression of coronary atherosclerosis. The purposes of this study were to compare electron beam CT and 16-MDCT scanners in the variability of repeated CAC measurements and to assess the factors influencing this variability.
Materials and methods: CAC models of different sizes attached to a cardiac phantom with a programmable variable heart rate were scanned three times, and interscan variability of the CAC measurement was calculated each time. For helical CT, different slice-thickness images of either retrospective ECG-gated or prospective ECG-triggering reconstruction were obtained. The detection of small amounts of calcium, variability of the Agatston score, and CAC measurement algorithms (Agatston, volume, and mass scores) were compared between CT scanners and protocols.
Results: All 1-mm-sized calcium models were detected on 0.625- and 1.25-mm helical CT, whereas some were missed on electron beam CT and 2.5-mm helical CT. Retrospective ECG-gated thin-slice helical CT showed the lowest variability. Reduction of variability by volume and mass scoring algorithms was less effective on 0.625- and 1.25-mm-thickness CT.
Conclusion: Retrospective ECG-gated thin-slice helical CT has the potential to be a useful tool for monitoring coronary atherosclerosis.
Similar articles
-
Variability of repeated coronary artery calcium measurements on low-dose ECG-gated 16-MDCT.AJR Am J Roentgenol. 2006 Jul;187(1):W1-6. doi: 10.2214/AJR.05.0052. AJR Am J Roentgenol. 2006. PMID: 16794121
-
Variability of repeated coronary artery calcium scoring and radiation Dose on 64- and 16-slice computed tomography by prospective electrocardiographically-triggered axial and retrospective electrocardiographically-gated spiral computed tomography: a phantom study.Acad Radiol. 2008 Aug;15(8):958-65. doi: 10.1016/j.acra.2008.03.007. Acad Radiol. 2008. PMID: 18620116
-
Variability of repeated coronary artery calcium measurements by 16-MDCT with retrospective reconstruction.AJR Am J Roentgenol. 2005 Jun;184(6):1917-23. doi: 10.2214/ajr.184.6.01841917. AJR Am J Roentgenol. 2005. PMID: 15908554
-
Electron beam CT versus helical CT scans for assessing coronary calcification: current utility and future directions.Am Heart J. 2003 Dec;146(6):969-77. doi: 10.1016/S0002-8703(03)00450-2. Am Heart J. 2003. PMID: 14660987 Review.
-
Coronary calcium measurements: effect of CT scanner type and calcium measure on rescan reproducibility--MESA study.Radiology. 2005 Aug;236(2):477-84. doi: 10.1148/radiol.2362040513. Epub 2005 Jun 21. Radiology. 2005. PMID: 15972340 Review.
Cited by
-
Evaluation of the influence of acquisition and reconstruction parameters for 16-row multidetector CT on coronary calcium scoring using a stationary and dynamic cardiac phantom.Eur Radiol. 2007 Aug;17(8):1985-94. doi: 10.1007/s00330-006-0564-z. Epub 2007 Feb 1. Eur Radiol. 2007. PMID: 17268802
-
[The research on cardiac volume-time relationship based on retrospective electrocardiograph four-dimension computer tomography data collection and structured sparse algorithm].Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2018 Apr 25;35(2):219-228. doi: 10.7507/1001-5515.201710042. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2018. PMID: 29745527 Free PMC article. Chinese.
-
Coronary calcium mass scores measured by identical 64-slice MDCT scanners are comparable: a cardiac phantom study.Int J Cardiovasc Imaging. 2010 Jan;26(1):89-98. doi: 10.1007/s10554-009-9503-9. Epub 2009 Sep 19. Int J Cardiovasc Imaging. 2010. PMID: 19768572 Free PMC article.
-
Dissociation between progression of coronary artery calcification and endothelial function in hemodialysis patients: a prospective pilot study.Clin Nephrol. 2012 Jul;78(1):1-9. doi: 10.5414/cn106830. Clin Nephrol. 2012. PMID: 22732331 Free PMC article. Clinical Trial.
-
Calcium scoring using 64-slice MDCT, dual source CT and EBT: a comparative phantom study.Int J Cardiovasc Imaging. 2008 Jun;24(5):547-56. doi: 10.1007/s10554-007-9282-0. Epub 2007 Nov 23. Int J Cardiovasc Imaging. 2008. PMID: 18038190 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical