Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1992 Jul;86(1):196-202.
doi: 10.1161/01.cir.86.1.196.

Hemodynamic evaluation before and after closure of fenestrated Fontan. An acute study of changes in oxygen delivery

Affiliations

Hemodynamic evaluation before and after closure of fenestrated Fontan. An acute study of changes in oxygen delivery

Z M Hijazi et al. Circulation. 1992 Jul.

Abstract

Background: Acute changes in hemodynamics and oxygen delivery accompanying temporary occlusion of atrial defects in 14 patients after a fenestrated Fontan procedure were evaluated at a median interval of 32 days after surgery to identify candidates for permanent transcatheter closure of their defects.

Methods and results: Patients ranged in age from 9 months to 33 years and in weight from 7.9 to 69 kg. Right atrial (RA), left atrial (LA), and aortic pressures, mixed venous (SmvO2) and aortic (SaO2) oxygen saturation, and whole-body oxygen consumption (VO2) were measured, and systemic blood flow (Qs), systemic oxygen transport (SOT), and oxygen extraction were calculated before and after occlusion. SmvO2, VO2, and RA pressures did not change, but SaO2 increased from 84 +/- 6% to 95 +/- 3% (p less than 0.05), and LA pressures fell from 5.1 +/- 3.6 to 3.7 +/- 2.2 mm Hg (p less than 0.05). Qs fell from 2.4 +/- 0.7 to 1.8 +/- 0.41.min-1.m-2 (p less than 0.05), SOT fell from 425 +/- 154 to 366 +/- 112 ml.O2.min-1.m-2 (p less than 0.05), and oxygen extraction increased from 0.40 +/- 0.12 to 0.46 +/- 0.13 (p less than 0.05). Only one patient did not undergo definitive closure of his defect because of a marked decrease in Qs and SOT with a significant rise in RA pressure.

Conclusions: Although delayed closure of an atrial defect in these patients improved morbidity and mortality, the complete separation of the venous and systemic circulations was accomplished at the expense of decreased Qs and oxygen delivery despite the improved level of arterial oxygenation. The resting levels of oxygen extraction are elevated and will be associated with decreased exercise capability. The long-term benefits of closure of these fenestrations are yet to be shown.