Scanning laser polarimetry using variable corneal compensation in the detection of glaucoma with localized visual field defects
- PMID: 16185765
- DOI: 10.1016/j.ophtha.2005.06.023
Scanning laser polarimetry using variable corneal compensation in the detection of glaucoma with localized visual field defects
Abstract
Purpose: To evaluate the ability of scanning laser polarimetry parameters and a novel deviation map algorithm to discriminate between healthy and early glaucomatous eyes with localized visual field (VF) defects confined to one hemifield.
Design: Prospective case-control study.
Participants: Seventy glaucomatous eyes with localized VF defects and 66 normal controls.
Methods: A Humphrey field analyzer 24-2 full-threshold test and scanning laser polarimetry with variable corneal compensation were used.
Main outcome measures: We assessed the sensitivity and specificity of scanning laser polarimetry parameters, sensitivity and cutoff values for scanning laser polarimetry deviation map algorithms at different specificity values (80%, 90%, and 95%) in the detection of glaucoma, and correlations between the algorithms of scanning laser polarimetry and of the pattern deviation derived from Humphrey field analyzer testing.
Results: There were significant differences between the glaucoma group and normal subjects in the mean parametric values of the temporal, superior, nasal, inferior, temporal (TSNIT) average, superior average, inferior average, and TSNIT standard deviation (SD) (P<0.05). The sensitivity and specificity of each scanning laser polarimetry variable was as follows: TSNIT, 44.3% (95% confidence interval [CI], 39.8%-49.8%) and 100% (95.4%-100%); superior average, 30% (25.5%-34.5%) and 97% (93.5%-100%); inferior average, 45.7% (42.2%-49.2%) and 100% (95.8%-100%); and TSNIT SD, 30% (25.9%-34.1%) and 97% (93.2%-100%), respectively (when abnormal was defined as P<0.05). Based on nerve fiber indicator cutoff values of > or =30 and > or =51 to indicate glaucoma, sensitivities were 54.3% (50.1%-58.5%) and 10% (6.4%-13.6%), and specificities were 97% (93.2%-100%) and 100% (95.8%-100%), respectively. The range of areas under the receiver operating characteristic curves using the scanning laser polarimetry deviation map algorithm was 0.790 to 0.879. Overall sensitivities combining each probability scale and severity score at 80%, 90%, and 95% specificities were 90.0% (95% CI, 86.4%-93.6%), 71.4% (67.4%-75.4%), and 60.0% (56.2%-63.8%), respectively. There was a statistically significant correlation between the scanning laser polarimetry severity score and the VF severity score (R2 = 0.360, P<0.001).
Conclusions: Scanning laser polarimetry parameters may not be sufficiently sensitive to detect glaucomatous patients with localized VF damage. Our algorithm using the scanning laser polarimetry deviation map may enhance the understanding of scanning laser polarimetry printouts in terms of the locality, deviation size, and severity of localized retinal nerve fiber layer defects in eyes with localized VF loss.
Similar articles
-
Scanning laser polarimetry of the retinal nerve fiber layer in perimetrically unaffected eyes of glaucoma patients.Ophthalmology. 2004 Dec;111(12):2199-203. doi: 10.1016/j.ophtha.2004.06.018. Ophthalmology. 2004. PMID: 15582074
-
Scanning laser polarimetry with variable corneal compensation in primary angle-closure glaucoma.Ophthalmology. 2008 Aug;115(8):1334-9. doi: 10.1016/j.ophtha.2007.10.042. Epub 2008 Jan 16. Ophthalmology. 2008. PMID: 18201763
-
Diagnostic accuracy of scanning laser polarimetry with enhanced versus variable corneal compensation.Ophthalmology. 2007 Nov;114(11):1988-93. doi: 10.1016/j.ophtha.2007.01.022. Epub 2007 Apr 24. Ophthalmology. 2007. PMID: 17459481
-
New developments in scanning laser polarimetry for glaucoma.Curr Opin Ophthalmol. 2008 Mar;19(2):136-40. doi: 10.1097/ICU.0b013e3282f4b1c2. Curr Opin Ophthalmol. 2008. PMID: 18301287 Review.
-
Computer-assisted interpretation of visual fields in glaucoma.Acta Ophthalmol Suppl (1985). 1992;(206):1-47. Acta Ophthalmol Suppl (1985). 1992. PMID: 1467748 Review.
Cited by
-
Optic nerve head and fibre layer imaging for diagnosing glaucoma.Cochrane Database Syst Rev. 2015 Nov 30;2015(11):CD008803. doi: 10.1002/14651858.CD008803.pub2. Cochrane Database Syst Rev. 2015. PMID: 26618332 Free PMC article.
-
The glaucoma detection capability of spectral-domain OCT and GDx-VCC deviation maps in early glaucoma patients with localized visual field defects.Graefes Arch Clin Exp Ophthalmol. 2013 Oct;251(10):2371-82. doi: 10.1007/s00417-013-2362-z. Epub 2013 Jul 3. Graefes Arch Clin Exp Ophthalmol. 2013. PMID: 23818227 Clinical Trial.
-
Scanning laser polarimetry and optical coherence tomography for detection of retinal nerve fiber layer defects.Korean J Ophthalmol. 2009 Sep;23(3):169-75. doi: 10.3341/kjo.2009.23.3.169. Epub 2009 Sep 8. Korean J Ophthalmol. 2009. PMID: 19794943 Free PMC article.
-
Relationship between scanning laser polarimetry with enhanced corneal compensation and with variable corneal compensation.Korean J Ophthalmol. 2008 Mar;22(1):18-25. doi: 10.3341/kjo.2008.22.1.18. Korean J Ophthalmol. 2008. PMID: 18323701 Free PMC article.
-
Twenty-four hour blood pressure pattern in patients with normal tension glaucoma in the habitual position.Korean J Ophthalmol. 2009 Mar;23(1):32-9. doi: 10.3341/kjo.2009.23.1.32. Epub 2009 Mar 9. Korean J Ophthalmol. 2009. PMID: 19337477 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical