Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2005 Oct;16(10):1064-70.
doi: 10.1111/j.1540-8167.2005.50103.x.

Transvenous cryoablation reduces platelet activation during pulmonary vein ablation compared with radiofrequency energy in patients with atrial fibrillation

Affiliations
Randomized Controlled Trial

Transvenous cryoablation reduces platelet activation during pulmonary vein ablation compared with radiofrequency energy in patients with atrial fibrillation

Hung-Fat Tse et al. J Cardiovasc Electrophysiol. 2005 Oct.

Abstract

Background: Radiofrequency (RF) ablation procedures for atrial fibrillation (AF) are associated with potential risks of thromboembolism, which may be minimized by the use of cryoablation that preserves the integrity of endocardium. The objective of this study was to compare the thrombogenic potential of transvenous cryoablation versus RF ablation during pulmonary vein (PV) isolation.

Methods and results: Thirty consecutive patients with paroxysmal AF were randomized to undergo segmental PV isolation procedure using 4-mm tip RF ablation (n = 15) or cryoablation (CryoCor, San Diego, CA, USA) (n = 15). Blood samples were drawn after sheath insertion (baseline), after transseptal puncture, before ablation (after heparin administration), and after isolation of a superior PV. Activation of coagulation was measured with plasma levels of prothrombin fragment 1 + 2 (F1 + 2) and thrombin-antithrombin III complex (TAT), and platelets by plasma level of beta-thromboglobulin (beta-TG) and flow cytometric enumerating of P-selectin (CD62)-positive platelets. In both groups, the plasma level of beta-TG, F1 + 2, and TAT were elevated after sheath insertion. The percentage changes in plasma level of beta-TG, F1 + 2, and TAT and CD41/62-positive platelets from baseline after transseptal puncture and before ablation were similar (P > 0.05). However, the percentage changes in CD62-positive platelets from baseline were significantly higher in patients treated with RF ablation (82 +/- 20%) than with cryoablation (22 +/- 14%, P = 0.02), although their plasma levels of beta-TG, F1 + 2, and TAT were not different (P > 0.05).

Conclusions: Significant platelet and coagulation activations were observed during PV ablation procedures, and heparin administration only prevented activation of coagulation but not platelets. Persistent platelets activation was observed during RF energy application, but not during cryoablation.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources