Normal mitral and aortic valve areas assessed by three- and two-dimensional echocardiography in 168 children and young adults
- PMID: 16193375
- DOI: 10.1007/s00246-005-1056-7
Normal mitral and aortic valve areas assessed by three- and two-dimensional echocardiography in 168 children and young adults
Abstract
Our purpose was to investigate the effects of body size on the sizes of mitral (MV) and aortic valve (AV) areas by three-dimensional (3-D) and two-dimensional (2-D) echocardiography and to create the normal values for 3-D echocardiography. A total of 168 healthy subjects aged 2-27 years were studied by digitized 3-DE, 2-DE, and Doppler echocardiography.3-D echocardiography was performed by using rotational acquisition of planes at 18 degrees intervals from a parasternal view with electrocardiogram gating and without respiratory gating. The annular levels of MV and AV were identified from short-axis cut planes and their areas were measured by planimetry. The diameters of mitral annulus, left ventricular outflow tract (LVOT), and aortic annulus were measured by 2-DE from the apical and parasternal long-axis views. Flow indices were measured by Doppler from MV inflow and the flow in LVOT and in the ascending aorta. Both MV and AV annular areas increased linearly in relation to body size. In the total study group the estimated areas for MV were 5.2 +/- 0.9 cm2/m2 by 3-DE, 3.7 +/- 0.5 cm2/m2 by 2-DE, and 2.0 +/- 0.4 cm2/m2 by continuity equation. The respective values for AV were 2.7 +/- 0.5, 2.1 +/- 0.3, and 1.8 +/- 0.4 cm2/m2. MV velocity time integral (VTI)/ascending aorta VTI increased from 0.80 (0.26) to 0.95 (0.23) with increased body surface area (BSA), whereas MV VTI/LVOT VTI was 1.2 (0.2) in all BSA groups. MV and AV annulus areas increase linearly in relation to body size. 3-DE gives greater estimates for the areas than 2-DE and Doppler equation methods. The data obtained from 168 healthy subjects may serve as a reference for clinical use in patients with various cardiac abnormalities.
Similar articles
-
Evaluation of a new 3-dimensional color Doppler flow method to quantify flow across the mitral valve and in the left ventricular outflow tract: an in vitro study.J Ultrasound Med. 2014 Feb;33(2):265-71. doi: 10.7863/ultra.33.2.265. J Ultrasound Med. 2014. PMID: 24449729
-
Effect of mitral valve repair on mitral-aortic coupling: a real-time three-dimensional transesophageal echocardiography study.J Am Soc Echocardiogr. 2012 May;25(5):524-31. doi: 10.1016/j.echo.2012.02.002. Epub 2012 Mar 8. J Am Soc Echocardiogr. 2012. PMID: 22406162
-
Age and body surface area dependency of mitral valve and papillary apparatus parameters: assessment by real-time three-dimensional echocardiography.Eur J Echocardiogr. 2009 Mar;10(2):287-94. doi: 10.1093/ejechocard/jen237. Epub 2008 Sep 16. Eur J Echocardiogr. 2009. PMID: 18799478
-
The mystery of defining aortic valve area: what have we learnt from three-dimensional imaging modalities?J Echocardiogr. 2018 Sep;16(3):130-138. doi: 10.1007/s12574-018-0374-8. Epub 2018 Feb 23. J Echocardiogr. 2018. PMID: 29476387 Review.
-
[Dimensions of the proximal thoracic aorta from childhood to adult age: reference values for two-dimensional echocardiography. Ligurian Group of SIEC (Italian Society of Echocardiography)].G Ital Cardiol. 1997 Jul;27(7):686-96. G Ital Cardiol. 1997. PMID: 9303859 Review. Italian.
Cited by
-
Relationship of Echocardiographic Z Scores Adjusted for Body Surface Area to Age, Sex, Race, and Ethnicity: The Pediatric Heart Network Normal Echocardiogram Database.Circ Cardiovasc Imaging. 2017 Nov;10(11):e006979. doi: 10.1161/CIRCIMAGING.117.006979. Circ Cardiovasc Imaging. 2017. PMID: 29138232 Free PMC article.
-
Comparison of two echocardiography-based methods for evaluating pediatric left ventricular diastolic dysfunction.Front Pediatr. 2023 Sep 4;11:1206314. doi: 10.3389/fped.2023.1206314. eCollection 2023. Front Pediatr. 2023. PMID: 37732011 Free PMC article.
-
Pediatric Echocardiographic Nomograms: Twenty Years of Advances-Do We Now Have a Complete and Reliable Tool, or Are Gaps Still Present? An Up-to-Date Review.J Clin Med. 2025 Jul 23;14(15):5215. doi: 10.3390/jcm14155215. J Clin Med. 2025. PMID: 40806837 Free PMC article. Review.
-
Comprehensive echocardiographic imaging of atrioventricular valves in children with atrioventricular septal defect: Accuracy of 2D and 3D imaging and reasons for disagreement.Anatol J Cardiol. 2019 Mar;21(4):214-221. doi: 10.14744/AnatolJCardiol.2019.49376. Anatol J Cardiol. 2019. PMID: 30930449 Free PMC article.
-
LVOT-VTI is a Useful Indicator of Low Ventricular Function in Young Patients.Pediatr Cardiol. 2017 Aug;38(6):1148-1154. doi: 10.1007/s00246-017-1630-9. Epub 2017 May 22. Pediatr Cardiol. 2017. PMID: 28534242
References