Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2006 Feb;364(1-2):180-7.
doi: 10.1016/j.cca.2005.06.016. Epub 2005 Sep 28.

Quantitative determination of guanidinoacetate and creatine in dried blood spot by flow injection analysis-electrospray tandem mass spectrometry

Affiliations
Comparative Study

Quantitative determination of guanidinoacetate and creatine in dried blood spot by flow injection analysis-electrospray tandem mass spectrometry

Claudia Carducci et al. Clin Chim Acta. 2006 Feb.

Abstract

Background: Guanidinoacetate (GAA) and creatine (Cr) are reliable biochemical markers of primary creatine disorders. The aim of this study was to develop and validate a method for the determination of GAA and Cr in dried blood spot through the use of stable isotope dilution and flow injection analysis (FIA)-ESI-MS/MS.

Methods: Dried blood spots were extracted using methanol-water solution containing D3-Cr. After evaporation and formation of butyl esters, samples were analyzed using multiple reaction monitoring mode (m/z 174.2-->101.1 for GAA, 188.3-->90.1 for Cr and 191.3-->93.1 for D3-Cr).

Results: The analysis was very fast (1 min). The detection limits were 0.34 micromol/l of blood and 0.30 micromol/l of blood for Cr and GAA, respectively, and the response was linear over the range 0.25-12.5 micromol/l of blood for GAA and 3.57-624.7 micromol/l of blood for Cr. Recovery range was 93-101% for Cr and 94-105% for GAA and between-run CVs were 5.3% for GAA and 4.5% for Cr. Ion suppression effect was also studied. The method was applied to spots obtained from two patients affected by GAMT deficiency, four patients affected by AGAT deficiency (including a newborn) as well as 282 healthy subjects.

Conclusions: The detection of GAA in dried blood spot by FIA-ESI-MS/MS is a highly reliable and high throughput method for the diagnosis of GAMT and AGAT deficiencies and a possible tool for newborn screening of both these tractable disorders.

PubMed Disclaimer

Publication types

MeSH terms

Associated data

LinkOut - more resources