Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2005 Oct;128(4):504-12.
doi: 10.1016/j.ajodo.2004.03.040.

The interaction between changes in upright mandibular position and supine airway size in patients with obstructive sleep apnea

Affiliations
Clinical Trial

The interaction between changes in upright mandibular position and supine airway size in patients with obstructive sleep apnea

Satoru Tsuiki et al. Am J Orthod Dentofacial Orthop. 2005 Oct.

Abstract

Introduction: The purpose of this study was to investigate the interaction between upright mandibular position change and supine upper airway size in men with obstructive sleep apnea fitted with titratable oral appliances.

Methods: Baseline supine cephalometry before placement of the oral appliance and after titration with the oral appliance in place were undertaken in 14 patients, and upright mandibular position change was evaluated with and without the titrated oral appliance in place with a DigiGraph workstation (Dolphin Imaging Systems, Valencia, Calif).

Results: The apnea-hypopnea index was significantly reduced after titration of the oral appliance (P < .01). Upright mandibular position change was associated with significant vertical (P < .01) and horizontal (P < .01) mandibular repositioning. The size of the supine velopharynx (P < .05), but not the supine oropharynx, was significantly enlarged at the titrated mandibular position. The supine oropharyngeal size change was correlated with the upright horizontal repositioning of the mandible (r = 0.69, P < .01).

Conclusions: Evaluation of upright mandibular position changes with the DigiGraph workstation enables one to predict supine oropharyngeal enlargement with oral appliance therapy. Dose-dependent effects of the horizontal component of upright mandibular protrusion on supine oropharyngeal size in addition to velopharyngeal enlargement might contribute to oral appliance effectiveness in obstructive sleep apnea patients.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources