Comparison of prone positioning and high-frequency oscillatory ventilation in patients with acute respiratory distress syndrome
- PMID: 16215365
- DOI: 10.1097/01.ccm.0000181298.05474.2b
Comparison of prone positioning and high-frequency oscillatory ventilation in patients with acute respiratory distress syndrome
Abstract
Objective: Both prone position and high-frequency oscillatory ventilation (HFOV) have the potential to facilitate lung recruitment, and their combined use could thus be synergetic on gas exchange. Keeping the lung open could also potentially be lung protective. The aim of this study was to compare physiologic and proinflammatory effects of HFOV, prone positioning, or their combination in severe acute respiratory distress syndrome (ARDS).
Design: : Prospective, comparative randomized study.
Setting: A medical intensive care unit.
Patients: Thirty-nine ARDS patients with a Pao2/Fio2 ratio <150 mm Hg at positive end-expiratory pressure > or =5 cm H2O.
Interventions: After 12 hrs on conventional lung-protective mechanical ventilation (tidal volume 6 mL/kg of ideal body weight, plateau pressure not exceeding the upper inflection point, and a maximum of 35 cm H2O; supine-CV), 39 patients were randomized to receive one of the following 12-hr periods: conventional lung-protective mechanical ventilation in prone position (prone-CV), HFOV in supine position (supine-HFOV), or HFOV in prone position (prone-HFOV).
Measurements and main results: Prone-CV (from 138 +/- 58 mm Hg to 217 +/- 110 mm Hg, p < .0001) and prone-HFOV (from 126 +/- 40 mm Hg to 227 +/- 64 mm Hg, p < 0.0001) improved the Pao2/Fio2 ratio whereas supine-HFOV did not alter the Pao2/Fio2 ratio (from 134 +/- 57 mm Hg to 138 +/- 48 mm Hg). The oxygenation index ({mean airway pressure x Fio2 x 100}/Pao2) decreased in the prone-CV and prone-HFOV groups and was lower than in the supine-HFOV group. Interleukin-8 increased significantly in the bronchoalveolar lavage fluid (BALF) in supine-HFOV and prone-HFOV groups compared with prone-CV and supine-CV. Neutrophil counts were higher in the supine-HFOV group than in the prone-CV group.
Conclusions: Although HFOV in the supine position does not improve oxygenation or lung inflammation, the prone position increases oxygenation and reduces lung inflammation in ARDS patients. Prone-HFOV produced similar improvement in oxygenation like prone-CV but was associated with higher BALF indexes of inflammation. In contrast, supine-HFOV did not improve gas exchange and was associated with enhanced lung inflammation.
Comment in
-
Prone position, high-frequency oscillatory ventilation, and Hippocrates in acute respiratory distress syndrome.Crit Care Med. 2005 Oct;33(10):2407-8. doi: 10.1097/01.ccm.0000182888.94728.3a. Crit Care Med. 2005. PMID: 16215399 No abstract available.
-
High-frequency oscillation and prone position.Crit Care Med. 2006 May;34(5):1578; author reply 1578-9. doi: 10.1097/01.CCM.0000216124.28529.39. Crit Care Med. 2006. PMID: 16633274 No abstract available.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources