In vivo multiple-mouse MRI at 7 Tesla
- PMID: 16215960
- DOI: 10.1002/mrm.20683
In vivo multiple-mouse MRI at 7 Tesla
Abstract
We developed a live high-field multiple-mouse magnetic resonance imaging method to increase the throughput of imaging studies involving large numbers of mice. Phantom experiments were performed in 7 shielded radiofrequency (RF) coils for concurrent imaging on a 7 Tesla MRI scanner outfitted with multiple transmit and receive channels to confirm uniform signal-to-noise ratio and minimal ghost artifacts across images from the different RF coils. Grid phantoms were used to measure image distortion in different positions in the coils. The brains of 7 live mice were imaged in 3D in the RF coil array, and a second array of 16 RF coils was used to 3D image the whole bodies of 16 fixed, contrast agent-perfused mice. The images of the 7 live mouse brains at 156 microm isotropic resolution and the 16 whole fixed mice at 100 microm isotropic resolution were of high quality and free of artifacts. We have thus shown that multiple-mouse MRI increases throughput for live and fixed mouse experiments by a factor equaling the number of RF coils in the scanner.
(c) 2005 Wiley-Liss, Inc.
Similar articles
-
Simultaneous PET/MR imaging: MR-based attenuation correction of local radiofrequency surface coils.Med Phys. 2012 Jul;39(7):4306-15. doi: 10.1118/1.4729716. Med Phys. 2012. PMID: 22830764
-
Performance of a miniature high-temperature superconducting (HTS) surface coil for in vivo microimaging of the mouse in a standard 1.5T clinical whole-body scanner.Magn Reson Med. 2008 Oct;60(4):917-27. doi: 10.1002/mrm.21605. Magn Reson Med. 2008. PMID: 18816812
-
Multiple-mouse MRI with multiple arrays of receive coils.Magn Reson Med. 2010 Mar;63(3):803-10. doi: 10.1002/mrm.22236. Magn Reson Med. 2010. PMID: 20146352 Free PMC article.
-
Mouse morphological phenotyping with magnetic resonance imaging.Methods Mol Med. 2006;124:103-27. doi: 10.1385/1-59745-010-3:103. Methods Mol Med. 2006. PMID: 16506419 Review.
-
Clinical applications of dual-channel transmit MRI: A review.J Magn Reson Imaging. 2015 Oct;42(4):855-69. doi: 10.1002/jmri.24791. Epub 2015 Apr 9. J Magn Reson Imaging. 2015. PMID: 25854179 Review.
Cited by
-
Small-animal MRI: signal-to-noise ratio comparison at 7 and 1.5 T with multiple-animal acquisition strategies.MAGMA. 2006 Sep;19(4):202-8. doi: 10.1007/s10334-006-0048-9. Epub 2006 Sep 7. MAGMA. 2006. PMID: 16957937
-
Neuronal overexpression of Ube3a isoform 2 causes behavioral impairments and neuroanatomical pathology relevant to 15q11.2-q13.3 duplication syndrome.Hum Mol Genet. 2017 Oct 15;26(20):3995-4010. doi: 10.1093/hmg/ddx289. Hum Mol Genet. 2017. PMID: 29016856 Free PMC article.
-
Sensitive Periods for Cerebellar-Mediated Autistic-like Behaviors.Cell Rep. 2018 Oct 9;25(2):357-367.e4. doi: 10.1016/j.celrep.2018.09.039. Cell Rep. 2018. PMID: 30304677 Free PMC article.
-
Foxp1 regulation of neonatal vocalizations via cortical development.Genes Dev. 2017 Oct 15;31(20):2039-2055. doi: 10.1101/gad.305037.117. Epub 2017 Nov 14. Genes Dev. 2017. PMID: 29138280 Free PMC article.
-
Mutation in the FUS nuclear localisation signal domain causes neurodevelopmental and systemic metabolic alterations.Dis Model Mech. 2023 Oct 1;16(10):dmm050200. doi: 10.1242/dmm.050200. Epub 2023 Oct 23. Dis Model Mech. 2023. PMID: 37772684 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical