Abstract
An on-line solid-phase extraction liquid chromatography/tandem mass spectrometry (SPE LC/MS/MS) assay using a newly developed SPE column and a monolithic column was developed and validated for direct analysis of plasma samples containing multiple analytes. This assay was developed in an effort to increase bioanalysis throughput and reduce the complexity of on-line SPE LC/MS/MS systems. A simple column-switching configuration that requires only one six-port valve and one HPLC pumping system was employed for on-line plasma sample preparation and subsequent gradient chromatographic separation. The resulting analytical method couples the desired sensitivity with ease of use. The method was found to perform satisfactorily for direct plasma analysis with respect to assay linearity, specificity, sensitivity, precision, accuracy, carryover, and short-term stability of an eight-analyte mixture in plasma. A gradient LC condition was applied to separate the eight analytes that cannot be distinctly differentiated by MS/MS. With a run time for every injection of 2.8 min, a minimum of 300 direct plasma injections were made on one on-line SPE column without noticeable changes in system performance. Due to the ruggedness and simplicity of this system, generic methods can be easily developed and applied to analyze a wide variety of compounds in a high-throughput manner without laborious off-line sample preparation.
Copyright (c) 2005 John Wiley & Sons, Ltd.
Similar articles
-
Ternary-column system for high-throughput direct-injection bioanalysis by liquid chromatography/tandem mass spectrometry.Rapid Commun Mass Spectrom. 2000;14(2):105-11. doi: 10.1002/(SICI)1097-0231(20000130)14:2<105::AID-RCM842>3.0.CO;2-Q. Rapid Commun Mass Spectrom. 2000. PMID: 10623938
-
Parallel extraction columns and parallel analytical columns coupled with liquid chromatography/tandem mass spectrometry for on-line simultaneous quantification of a drug candidate and its six metabolites in dog plasma.Rapid Commun Mass Spectrom. 2001;15(22):2135-44. doi: 10.1002/rcm.492. Rapid Commun Mass Spectrom. 2001. PMID: 11746878
-
High-speed gradient parallel liquid chromatography/tandem mass spectrometry with fully automated sample preparation for bioanalysis: 30 seconds per sample from plasma.Rapid Commun Mass Spectrom. 2002;16(11):1116-23. doi: 10.1002/rcm.688. Rapid Commun Mass Spectrom. 2002. PMID: 11992516
-
Recent advances in high-throughput quantitative bioanalysis by LC-MS/MS.J Pharm Biomed Anal. 2007 Jun 28;44(2):342-55. doi: 10.1016/j.jpba.2007.02.006. Epub 2007 Feb 13. J Pharm Biomed Anal. 2007. PMID: 17360141 Review.
-
High-throughput quantitative bioanalysis by LC/MS/MS.Biomed Chromatogr. 2000 Oct;14(6):422-9. doi: 10.1002/1099-0801(200010)14:6<422::AID-BMC25>3.0.CO;2-I. Biomed Chromatogr. 2000. PMID: 11002279 Review.
Cited by
-
Quantitative determination of total methamphetamine and active metabolites in rat tissue by liquid chromatography with tandem mass spectrometric detection.AAPS J. 2006 Nov 22;8(4):E709-17. doi: 10.1208/aapsj080480. AAPS J. 2006. PMID: 17233534 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical