Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006 Feb;61(2):111-4.
doi: 10.1136/thx.2005.046615. Epub 2005 Oct 14.

Mid-expiratory flow versus FEV1 measurements in the diagnosis of exercise induced asthma in elite athletes

Affiliations

Mid-expiratory flow versus FEV1 measurements in the diagnosis of exercise induced asthma in elite athletes

J W Dickinson et al. Thorax. 2006 Feb.

Abstract

Background: A fall in FEV(1) of > or =10% following bronchoprovocation (eucapnic voluntary hyperventilation (EVH) or exercise) is regarded as the gold standard criterion for diagnosing exercise induced asthma (EIA) in athletes. Previous studies have suggested that mid-expiratory flow (FEF(50)) might be used to supplement FEV(1) to improve the sensitivity and specificity of the diagnosis. A study was undertaken to investigate the response of FEF(50) following EVH or exercise challenges in elite athletes as an adjunct to FEV(1).

Methods: Sixty six male (36 asthmatic, 30 non-asthmatic) and 50 female (24 asthmatic, 26 non-asthmatic) elite athletes volunteered for the study. Maximal voluntary flow-volume loops were measured before and 3, 5, 10, and 15 minutes after stopping EVH or exercise. A fall in FEV(1) of > or =10% and a fall in FEF(50) of > or =26% were used as the cut off criteria for identification of EIA.

Results: There was a strong correlation between DeltaFEV(1) and DeltaFEF(50) following bronchoprovocation (r = 0.94, p = 0.000). Sixty athletes had a fall in FEV(1) of > or =10% leading to the diagnosis of EIA. Using the FEF(50) criterion alone led to 21 (35%) of these asthmatic athletes receiving a false negative diagnosis. The lowest fall in FEF(50) in an athlete with a > or =10% fall in FEV(1) was 14.3%. Reducing the FEF(50) criteria to > or =14% led to 13 athletes receiving a false positive diagnosis. Only one athlete had a fall in FEF(50) of > or =26% in the absence of a fall in FEV(1) of > or =10% (DeltaFEV(1) = 8.9%).

Conclusion: The inclusion of FEF(50) in the diagnosis of EIA in elite athletes reduces the sensitivity and does not enhance the sensitivity or specificity of the diagnosis. The use of FEF(50) alone is insufficiently sensitive to diagnose EIA reliably in elite athletes.

PubMed Disclaimer

Conflict of interest statement

Competing interests: none declared

Comment in

Similar articles

Cited by

References

    1. Lacroix V. Exercise induced asthma. Physician Sports Med 19992775–92. - PubMed
    1. Weiler J, Layton T, Hunt M. Asthma in United States Olympic athletes who participated in the 1996 Summer Olympic Games. J Allergy Clin Immunol 1998102722–726. - PubMed
    1. Wilber R, Rundell K, Szemdra L.et al Incidence of exercise induced bronchospasm in Olympic winter sport athletes. Med Sci Sports Exerc 200032732–737. - PubMed
    1. Larsson K, Ohlsen P, Larrson L.et al High prevalence of asthma in cross‐country skiers. BMJ 19933071326–1329. - PMC - PubMed
    1. Helenius I, Tikkanen H, Haahtela T. Occurrence of exercise induced bronchospasm in elite runners: dependence on atopy and exposure to cold air and pollen. Br J Sports Med 199832125–129. - PMC - PubMed

Publication types