Carotid stenosis degree in CT angiography: assessment based on luminal area versus luminal diameter measurements

Affiliations

Carotid stenosis degree in CT angiography: assessment based on luminal area versus luminal diameter measurements

Zishu Zhang et al. Eur Radiol. 2005 Nov.

Abstract

The aim of this study was to investigate CT angiography (CTA) luminal area measurements in the assessment of carotid artery stenosis compared with the current clinically used criteria based on lumen diameter measurements. Seventy-two vessels in 36 patients were evaluated by CTA and digital subtraction angiography (DSA). Two observers measured area and diameter stenosis degrees using automated 3D CTA analysis software. The ratio of the largest/smallest luminal diameter at the level of maximal stenosis (L/S ratio) was used to describe lumen morphology. Diagnostic agreement between CTA and DSA was calculated. For the assessment of area stenosis, interobserver and intraobserver correlation coefficients were 0.898 and 0.906 (p<0.001). The correlation coefficient between the diameter stenosis and area stenosis was lower in stenoses with extremely noncircular lumen (L/S ratio>or=1.5) (r=0.797, p<0.001) compared with stenoses with circular lumen (LS ratio<1.2) (r=0.978, p<0.001). Only satisfactory agreement (kappa 0.54-0.77, p<0.001) was obtained between area stenosis on CTA and diameter stenosis on DSA. Assessment of stenosis degree with area measurements on 3D CTA proved to be reproducible. Area stenosis provides a less-severe estimate of the degree of carotid stenosis but might theoretically express the real hemodynamic significance of the lesion better than diameter stenosis, especially in stenoses with noncircular lumen.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Eur Radiol. 2004 Apr;14 (4):665-72 - PubMed
    1. J Vasc Surg. 1998 Aug;28(2):290-300 - PubMed
    1. AJNR Am J Neuroradiol. 1997 Sep;18(8):1507-14 - PubMed
    1. Int J Cardiol. 2002 Nov;86(1):99-105 - PubMed
    1. Radiology. 1994 Oct;193(1):219-26 - PubMed

Publication types