[Tesio catheters for long-term hemodialysis: our experience in a comarcal hospital]
- PMID: 16231507
[Tesio catheters for long-term hemodialysis: our experience in a comarcal hospital]
Abstract
Introduction: Good vascular access remains the cornerstone of effective hemodialysis treatment. The Tesio catheters has been proposed to be a reliable source of vascular access for the dialysis patients.
Subjects and methods: We examined all Tesio catheters inserted over a 3-year period in our hospital. We obtained age, sex, dialysis duration, original nephropaty, vascular access history, complications, dialysis parameters, catheter function duration, confort level for patients and nurses, and death in all our cases.
Results: 33 catheters were inserted in 30 patients, 14 male and 16 female. Age 73,92 +/- 9,22 years. Dialysis duration, 25,64 +/- 53,45 months. Diabetic nephropaty 26,66%, NAE 40%, others 33,33%. First vascular access in 13 patients (43,33%), one previously fistula, 5 patients (16,66%), and more of one FAV, 12 patients (40%). We observed two bleeding cases, eight parcial trombosis, one total trombosis (non-function), six tunneled infection and two systemic infection. Only 3 catheters were removal. We obteined good dialysis parameters. Confort state for patients and nurses were satisfactory. Death 12 patients. Catheter function at the moment of study 16,76 +/-12,99 months.
Conclusions: We concluded that Tesio catheters can provide excellent long-term vascular access for hemodialysis patients, especially in the older people and with some previous failure fistulas, with low complication rates and acceptable dialysis parameters and tolerance. However, the arteriovenous fistula remains the gold standard for long-term hemodialysis access.
Similar articles
-
Tesio-Caths provide effective and safe long-term vascular access.Nephrol Dial Transplant. 2004 Nov;19(11):2816-22. doi: 10.1093/ndt/gfh467. Epub 2004 Aug 31. Nephrol Dial Transplant. 2004. PMID: 15340094
-
Do central venous catheters have advantages over arteriovenous fistulas or grafts?J Nephrol. 2006 May-Jun;19(3):265-79. J Nephrol. 2006. PMID: 16874685 Review.
-
[Fistulae or catheter for elderly who start hemodialysis without permanent vascular access?].Nefrologia. 2005;25(3):307-14. Nefrologia. 2005. PMID: 16053012 Spanish.
-
Ethical and legal obligation to avoid long-term tunneled catheter access.Clin J Am Soc Nephrol. 2009 Feb;4(2):456-60. doi: 10.2215/CJN.03840808. Epub 2009 Jan 21. Clin J Am Soc Nephrol. 2009. PMID: 19158368 Review.
-
[Tesio twin catheter system for hemodialysis tunnelized using an echo-guided technique. Retrospective analysis of 210 catheters].Nefrologia. 2006;26(6):719-25. Nefrologia. 2006. PMID: 17227250 Spanish.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical