Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2005 Dec 27;829(1-2):69-74.
doi: 10.1016/j.jchromb.2005.09.035. Epub 2005 Oct 17.

Rapid and sensitive method for the determination of sertraline in human plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS)

Affiliations

Rapid and sensitive method for the determination of sertraline in human plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS)

Deepak S Jain et al. J Chromatogr B Analyt Technol Biomed Life Sci. .

Abstract

A method for the determination of sertraline, a new antidepressant drug and a selective serotonin reuptake inhibitor (SSRI), in human plasma is described. Therapeutic drug monitoring (TDM) necessitates efficient, fast and reliable analytical methods validated by external quality control. We therefore devised a simple, rapid and sensitive isocratic reversed-phase liquid chromatographic-tandem mass spectrometric method equipped with Turbo Ion spray (TIS) source, operating in the positive ion and selective reaction monitoring (SRM) acquisition mode to quantify sertraline in human plasma. A new and superior procedure of solid-phase extraction (SPE) (compared to liquid-liquid extraction) was followed to extract sertraline and imipramine as internal standard (IS) from the human plasma. Sample preparation was performed using waters hydrophilic-lipophilic balance (HLB) cartridge and this method yielded extremely clean extracts with very good recovery, 81.47 and 85.79% for sertraline and IS, respectively. Both were analyzed by combined reverse phase liquid chromatography and tandem mass spectrometry (LC-MS/MS) with positive ion TIS ionization using SRM acquisition mode. The response of the LC-MS/MS method for sertraline was linear over the dynamic range of 0.5-60.0 ng/ml with correlation coefficient r>or=0.9996. The coefficient of variance (%CV) was 8.53% at 0.5 ng/ml and the accuracy was well within the accepted limit of +/-20% at lower limit of quantification (LLOQ) and +/-15% at all the other concentrations in the linear range. This method was fully validated for the accuracy, precision and stability studies. The above findings indicate that the method is very much accurate and precise and can be successfully applied for bioequivalence studies in human subjects.

PubMed Disclaimer

LinkOut - more resources